<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ElectriCasas &#187; Conductores</title>
	<atom:link href="http://www.electricasas.com/electricasas/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.electricasas.com</link>
	<description>Electricidad del Hogar y Electrónica Facil</description>
	<lastBuildDate>Tue, 23 Feb 2010 21:33:25 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.8.1</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Cables coaxiles</title>
		<link>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/cables-coaxiles/</link>
		<comments>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/cables-coaxiles/#comments</comments>
		<pubDate>Tue, 24 Feb 2009 00:14:42 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Conductores]]></category>
		<category><![CDATA[50 Ohm]]></category>
		<category><![CDATA[75 Ohm]]></category>
		<category><![CDATA[Aislante]]></category>
		<category><![CDATA[Cable coaxial]]></category>
		<category><![CDATA[Cables coaxiles]]></category>
		<category><![CDATA[Capacidad]]></category>
		<category><![CDATA[Características constructivas]]></category>
		<category><![CDATA[Conductor central]]></category>
		<category><![CDATA[Conductor externo]]></category>
		<category><![CDATA[Cubierta externa]]></category>
		<category><![CDATA[Elección del cable coaxil]]></category>
		<category><![CDATA[Impedancia característica]]></category>
		<category><![CDATA[Impedancia transferencia]]></category>
		<category><![CDATA[Normas de aplicación]]></category>
		<category><![CDATA[Parámetros característicos]]></category>
		<category><![CDATA[Potencia transmisible]]></category>
		<category><![CDATA[Structural return loss]]></category>
		<category><![CDATA[Tension de trabajo]]></category>
		<category><![CDATA[Velocidad de propagación]]></category>

		<guid isPermaLink="false">http://www.electricasas.com/?p=2433</guid>
		<description><![CDATA[



Introducción
Las líneas para la transmisión a distancia de la voz humana, señales de vídeo, datos, etcétera, están constituidas por circuitos que transmiten ondas de tensión y de corriente con muy baja potencia y frecuencia muy elevada.
Hasta hace unos años, el diseño de redes de datos pequeñas y medianas solía ser un tema sencillo que no [...]]]></description>
			<content:encoded><![CDATA[<p><strong>Introducción</strong></p>
<p>Las líneas para la transmisión a distancia de la voz humana, señales de vídeo, datos, etcétera, están constituidas por circuitos que transmiten ondas de tensión y de corriente con muy baja potencia y frecuencia muy elevada.</p>
<p>Hasta hace unos años, el diseño de redes de datos pequeñas y medianas solía ser un tema sencillo que no presentaba problemas. Consistía en asegurarse de tener un buen cableado, colocar suficientes bocas e instalar uno o varios hubs.<br />
Con el advenimiento de aplicaciones cada vez más complejas, el aumento de los requerimientos de ancho de banda, que son muy superiores a los de hace algunos años, y la explosión del acceso a Internet, el diseño se ha convertido en algo complejo, a pesar de las mejoras en el rendimiento de los equipos y las capacidades del medio.</p>
<p>La tendencia actual apunta hacia múltiples medios de transmisión, múltiples protocolos e interconexiones entre diferentes redes internas y externas.</p>
<p style="text-align: center;"><a href="http://www.electricasas.com/wp-content/uploads/2009/02/coaxil-1.jpg"><img class="size-medium wp-image-2434 aligncenter" title="coaxil-1" src="http://www.electricasas.com/wp-content/uploads/2009/02/coaxil-1-300x251.jpg" alt="" width="300" height="251" /></a></p>
<p><span id="more-2433"></span></p>
<p>Existen tres tipos básicos de cableado de datos: cable coaxil, fibra óptica o par trenzado.</p>
<ul>
<li>Cable coaxil (o coaxial): Es el tipo de cable de cobre o aluminio que usan las empresas de televisión por cable (CATV) entre su antena comunitaria y las casas de los usuarios. A veces lo emplean las compañías telefónicas y es ampliamente usado en las redes de área local (LAN) de las empresas. Puede transportar señales análogas y de voz. Fue inventado en 1929 y usado comercialmente por primera vez en 1941. AT&amp;T tendió su primer sistema de transmisión coaxil intercontinental en 1940. Según el tipo de tecnología que se use, se lo puede reemplazar por fibra óptica.</li>
<li>Fibra óptica: tecnología para transmitir información como pulsos luminosos a través de un conducto de fibra de vidrio. La fibra óptica transporta mucha más información que el cable de cobre convencional. La mayoría de las líneas de larga distancia de las compañías telefónicas utilizan fibra óptica.</li>
<li>Par trenzado: Es el tipo de cable que se usa en telefonía y consta de dos conductores de cobre o aluminio que se disponen uno al lado del otro. Los dos conductores, uno de ida y el otro de retorno, necesarios para la transmisión, constituyen el llamado &#8220;par&#8221;.</li>
</ul>
<p>Los cables coaxiles se pueden emplear en todas aquellas aplicaciones donde se deba transmitir señales eléctricas a alta velocidad y sin la interferencia de otras señales espurias. Existen innumerables casos de este tipo, como ser las bajadas de antenas satelitales o de radiofrecuencia, las conexiones entre computadoras, las redes de televisión por cable, etcétera.</p>
<p>Se define como coaxil al cable en el cual los dos conductores tienen el mismo eje, siendo el conductor externo un cilindro separado del conductor interno por medio de un material dieléctrico. El conductor externo, además de conductor de retorno, cumple la función de blindaje, con la consiguiente estabilización de los parámetros eléctricos.</p>
<p>El empleo de cables coaxiles permite confinar la señal y limitar las pérdidas que se verifican por radiación cuando las frecuencias de las señales transmitidas sobrepasan los cientos de kHz.</p>
<p><strong>Parámetros característicos</strong></p>
<ul>
<li>Impedancia característica (Ohm):<br />
Es la relación tensión aplicada / corriente absorbida por un cable coaxil de longitud infinita. Puede demostrarse que, para un cable coaxil de longitud real conectado a una impedancia exactamente igual a la característica, el valor de la impedancia de la línea permanece igual al de la impedancia característica.<br />
Cabe recordar que en un sistema que trabaja a máxima eficiencia, la impedancia del transmisor, la del receptor y la del cable deben ser iguales, de no ser así se producirán reflexiones que degradarán el funcionamiento del sistema.<br />
La impedancia característica no depende de la longitud del cable ni de la frecuencia. Los valores nominales para los cables coaxiles son 50, 75 y 93 Ohm.</li>
<li>Impedancia transferencia (Ohm/m):<br />
Define la eficiencia del blindaje del conductor externo. Expresada habitualmente en miliohm por metro. Cuanto más pequeño es el valor, mejor es el cable a los efectos de la propagación al exterior de la señal transmitida y de la penetración en el cable de las señales externas.</li>
<li>Capacidad (F/m):<br />
Es el valor de la capacidad eléctrica, medida entre el conductor central y el conductor externo, dividida por la longitud del cable. Se trata de valores muy pequeños expresados en picofarad por metro. Varia con el tipo de material aislante y con la geometría del cable.</li>
<li>Velocidad de propagación (%):<br />
Es la relación, expresada porcentualmente, entre la velocidad de propagación de la señal en el cable y la velocidad de propagación de la luz en el vacío. Varía con el tipo de material aislante, en función de su constante dieléctrica.</li>
<li>Atenuacion (dB/m):<br />
Es la pérdida de potencia, a una determinada frecuencia, expresada generalmente en decibel cada 100 metros. Varía con el tipo de material empleado y con la geometría del cable, incrementándose al crecer la frecuencia.</li>
<li>Potencia transmisible (W):<br />
Es la potencia que se puede transmitir a una determinada frecuencia sin que la temperatura del cable afecte el funcionamiento del mismo. Disminuye al aumentar la frecuencia y se mide en Watt.</li>
<li>Tension de trabajo (kV):<br />
Es la máxima tensión entre el conductor externo e interno a la cual puede trabajar constantemente el cable sin que se generen las nocivas consecuencias del &#8220;efecto corona&#8221; (descargas eléctricas parciales que provocan interferencias eléctricas y, a largo plazo, la degradación irreversible del aislante).</li>
<li>Structural return loss (S.R.L.):<br />
Son las pérdidas por retorno ocasionadas por falta de uniformidad en la construcción (variación de los parámetros dimensionales) y en los materiales empleados, que producen una variación localizada de impedancia, provocando un &#8220;rebote&#8221; de la señal con la consiguiente inversión parcial de la misma.</li>
</ul>
<p><strong>Características constructivas</strong></p>
<p>A continuación se presenta un resumen de los principales materiales empleados para la construcción de cables coaxiles.</p>
<p style="text-align: center;"><a href="http://www.electricasas.com/wp-content/uploads/2009/02/cable_coaxial2.gif"><img class="size-full wp-image-2435 aligncenter" title="cable_coaxial2" src="http://www.electricasas.com/wp-content/uploads/2009/02/cable_coaxial2.gif" alt="" width="345" height="116" /></a></p>
<p>A) Conductor central:</p>
<ul>
<li>Cobre electrolítico, con pureza superior al 99% y resistividad nominal a 20°C de 17,241 Ohm mm² / km.</li>
<li>Cobre estañado, limitado a los cables empleados en aparatos que requieran buenas condiciones de soldabilidad (su uso incrementa la atenuación con respecto al cobre solo).</li>
<li>Cobre plateado, para mejorar la atenuación a altísima frecuencia y por su estabilidad química en presencia de dieléctricos fluorados.</li>
<li>Acero cobreado (copperweld), alambre obtenido por trefilación de cobre sobre un alma de acero. Si bien su conductividad normal es del 30% al 40% de la del cobre, a altas frecuencias (MHz) su conductividad es prácticamente idéntica a la del cobre, a raíz del efecto pelicular (skin effect); mientras la carga de rotura mínima es 77 kg / mm² y el alargamiento el 1% mínimo. Este material se emplea por razones mecánicas en los cables de secciones menores.</li>
</ul>
<p>B) Aislante:</p>
<ul>
<li>Polietileno compacto: es el material más empleado como aislante en los cables coaxiles, a raiz de su excelente constante dieléctrica relativa (2,25) y rigidez dieléctrica (18 kV/mm).</li>
<li>Polietileno expandido: se obtiene introduciendo en el polietileno sustancias que se descompongan con la temperatura generando gases, con la particularidad de que los poros quedan uniformemente distribuidos y sin comunicación entre sí. La misma expansión se puede obtener con inyección de gas en el momento de la extrusión, obteniendo características eléctricas superiores.<br />
Este material, de reducida constante dieléctrica (1,4 / 1,8, dependiendo del grado de expansión) y bajo factor de pérdida (tgd = 0,2 . 10-3), permite lograr una notable reducción de la atenuación, comparándola con el uso de polietileno compacto.</li>
<li>Polietileno/aire: es obtenido por la aplicación de una espiral de polietileno alrededor del conductor central, a su vez recubierto con un tubo extruido de polietileno.</li>
<li>Tefzel (copolímero etileno &#8211; tetrafluoroetileno): se emplea para temperaturas entre -50°C a +155 °C, con una constante dieléctrica de 2,6 y una rigidez dieléctrica de 80 kV/mm.</li>
<li>Teflón FEP (copolímero tetrafluoroetileno &#8211; exafluoropropileno): se emplea para temperaturas entre -70 °C y +200 °C, con constante dieléctrica de 2,1 y rigidez dieléctrica de 50 kV/mm.</li>
</ul>
<p>Estos dos últimos materiales se emplean, además de las aplicaciones de altas temperaturas para aplicaciones militares, electrónica, misiles, etc., en donde se requiera gran resistencia a los agentes químicos orgánicos e inorgánicos.</p>
<p>C) Conductor externo:</p>
<ul>
<li>Cobre: generalmente bajo la forma de trenza constituida por 16, 24 o 36 husos, con ángulos entre 30 y 45°.</li>
<li>Cobre estañado: cuando se necesitan buenas condiciones de soldabilidad.</li>
<li>Cobre plateado: en presencia de aislantes fluorados (estabilidad química).</li>
<li>Cintas de aluminio/poliester y aluminio/polipropileno: aplicadas debajo de la trenza reducen notablemente el efecto radiante y disminuyen la penetración de señales externas.</li>
</ul>
<p>D) Cubierta externa:</p>
<ul>
<li>Cloruro de polivinilo (PVC): es el material más empleado como cubierta, pudiéndose modificar sus características en función de exigencias específicas (bajas o altas temperaturas, no propagación del incendio, resistencia a los hidrocarburos, etc).<br />
Uno de los requisitos básicos para el PVC de la cubierta es no contaminar, con la migración de su plastificante, el aislante interno; si esto ocurre, al cabo del tiempo se pueden deteriorar las características eléctricas del aislante, produciéndose un constante aumento de la atenuación.</li>
<li>Polietileno: con una adecuada dispersión de negro de humo para mejorar su resistencia a las radiaciones ultravioletas.</li>
<li>Materiales fluorados (Tefzel y Teflón FEP): para empleo con altas temperaturas o en presencia de agentes químicos.</li>
</ul>
<p>Poliuretano: cuando se necesiten buenas características mecánicas.</p>
<p>E) Armaduras:</p>
<p>Alambres de acero: puestos bajo la forma de trenza o espiral, para instalaciones subterráneas.</p>
<p>F) Elementos autoportantes:</p>
<p>En las instalaciones aéreas para sustentar el cable se emplean construcciones especiales que preveen un alambre o cuerda de acero paralelo al cable coaxil envolviendo los dos elementos, conjuntamente con una cubierta de PVC o polietileno, formando un perfil en forma de &#8220;ocho&#8221;.</p>
<p><strong>Elección del cable coaxil</strong></p>
<p>Los cables coaxiles se eligen en base a los siguientes parámetros, que son impuestos por el circuito al que deberán ser conectados:</p>
<ul>
<li>Impedancia característica (50, 75 o 93 Ohm)</li>
<li>Frecuencia de trabajo (de 100 kHz a 3000 MHz</li>
<li>Atenuación máxima (de 1 a varios cientos de dB/100 m.) y/o potencia máxima (de unos pocos W hasta algún kW, referido a una frecuencia de trabajo).</li>
<li>Capacidad (de 30 a 100 pF/m)</li>
<li>Máxima tensión de señal</li>
<li>Aunque de menor importancia, en ciertas aplicaciones se requiere considerar también la velocidad de propagación y la impedancia de transferencia.</li>
</ul>
<p>Una vez definida la impedancia se puede elegir el cable operando sobre el correspondiente gráfico de los cables normalizados; con el valor de la frecuencia de trabajo se individualiza el punto de intersección correspondiente a la atenuación o potencia. Es suficiente adoptar el valor del diámetro D inmediatamente superior para definir en forma unívoca el tipo de cable adecuado.<br />
En caso de no encontrarse un cable normalizado se deberá recurrir a un diseño especial.</p>
<p><strong>Normas de aplicación</strong></p>
<p>La especificación más difundida que rige la fabricación de los cables coaxiles es la norma militar del gobierno de los Estados Unidos MIL-C-17 que, además de las características dimensionales y eléctricas, define una sigla que identifica a cada tipo de cable.<br />
Todos los cables coaxiles están definidos con las letras RG (radiofrecuencia &#8211; gobierno) seguida por un número (numeración progresiva del tipo) y de la letra U (especificación universal) o A/U, B/U, etc. que indican sucesivas modificaciones y sustituciones al tipo original.</p>
<p><strong>Algunos cables típicos</strong></p>
<p><strong>De 50 Ohm</strong>:</p>
<p>Utilizado en comunicaciones e intercomunicación de instrumentación de todo tipo: Interfaces, PC., equipos e instrumental de laboratorio, etc. El más utilizado es el RG-58 estañado pero se fabrican en un gran numero de variantes para cubrir los distintos requerimientos eléctricos y mecánicos. Por ejemplo los cables que tienen cuerda de cobre priorizan la flexibilidad y los de aislación FOAM poseen mejores performances eléctricas. Para radiofrecuencia, computación y antenas.</p>
<p><strong>De 75 Ohm</strong>:</p>
<p>Aislación compacta: Para radiofrecuencia, CCTV, CATV, señales de televisión y FM. El RG-59 es el coaxil de 75 Ohm de mayor venta en el mercado debido a sus excelentes características eléctricas y mecánicas combinadas con un bajo costo. Para tendidos de gran longitud se utiliza el RG-11 de mayor diámetro y por lo tanto menores perdidas. Aislación FOAM: Los coaxiles de aislación FOAM tienen menor atenuación de la señal que transportan que los de aislación compacta y mejores prestaciones a frecuencias elevadas. Combinan bajo peso y costo con un excepcional rendimiento eléctrico donde no se requiera gran resistencia mecánica. Además de la malla metálica, posee una pantalla de aluminio que garantiza una cobertura y blindaje del 100%.evitando interferencia externas.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/cables-coaxiles/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Intensidad máxima admisible en cables subterráneos</title>
		<link>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/intensidad-maxima-admisible-en-cables-subterraneos/</link>
		<comments>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/intensidad-maxima-admisible-en-cables-subterraneos/#comments</comments>
		<pubDate>Sun, 09 Nov 2008 21:56:16 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Conductores]]></category>
		<category><![CDATA[Cables enterrados en zanja]]></category>
		<category><![CDATA[cables monofasicos]]></category>
		<category><![CDATA[cables trifásicos]]></category>
		<category><![CDATA[Condiciones de instalación al aire]]></category>
		<category><![CDATA[Condiciones especiales]]></category>
		<category><![CDATA[Condiciones tipo de instalación enterrada]]></category>
		<category><![CDATA[factores de corrección de intensidad]]></category>
		<category><![CDATA[Intensidad máxima admisible en cables subterráneos]]></category>
		<category><![CDATA[Intensidades máximas permanentes]]></category>
		<category><![CDATA[temperaturas máximas admisibles]]></category>
		<category><![CDATA[Tipo de aislamiento]]></category>

		<guid isPermaLink="false">http://www.electricasas.com/?p=1642</guid>
		<description><![CDATA[1.1. Intensidades máximas permanentes en los conductores de los cables:
En las tablas que siguen se dan los valores indicados en la Norma UNE 20.435.
En la tabla 2 se dan las temperaturas máximas admisibles en el conductor según los tipos de aislamiento.
En las tablas 3, 4 y 5 se indican las intensidades máximas permanentes admisibles en [...]]]></description>
			<content:encoded><![CDATA[<p>1.1. Intensidades máximas permanentes en los conductores de los cables:</p>
<p>En las tablas que siguen se dan los valores indicados en la Norma UNE 20.435.</p>
<p>En la tabla 2 se dan las temperaturas máximas admisibles en el conductor según los tipos de aislamiento.</p>
<p>En las tablas 3, 4 y 5 se indican las intensidades máximas permanentes admisibles en los diferentes tipos de cables, en las condiciones tipo de instalación enterrada indicadas en el apartado 1.1.2.1. En las condiciones especiales de instalación indicadas en el apartado 1.1.2.2 se aplicarán los factores de corrección que correspondan según las tablas 6 a 9. Dichos factores de corrección se indican para cada condición que pueda diferenciar la instalación considerada de la instalación tipo.</p>
<p>En las tablas 10, 11 y 12 se indican las intensidades máximas permanentes admisibles en los diferentes tipos de cables, en las condiciones tipo de instalación al aire indicadas en el apartado 1.1.4.1. En las condiciones especiales de instalación indicadas en el apartado 1.1.4.2 se aplicarán los factores de corrección que corresponda, tablas 13 a 15. Dichos factores de corrección se indican para cada condición que pueda diferenciar la instalación considerada de la instalación tipo.<br />
 </p>
<p>1.1.1 Temperatura máxima admisible.</p>
<p>Las intensidades máximas admisibles en servicio permanente dependen en cada caso de la temperatura máxima que el aislamiento pueda soportar sin alteraciones de sus propiedades eléctricas, mecánicas o químicas. Esta temperatura es función del tipo de aislamiento y del régimen de carga.</p>
<p>En la tabla 2 se especifican, con carácter informativo, las temperaturas máximas admisibles, en servicio permanente y en cortocircuito, para algunos tipos de cables aislados con aislamiento seco.</p>
<table border="1" cellspacing="1" cellpadding="3" width="360">
<tbody>
<tr>
<td rowspan="2" width="217" valign="middle">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px"><strong>Tipo de</strong></p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px"><strong>Aislamiento seco</strong></p>
</td>
<td colspan="2" width="198" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px"><strong>Temperatura máxima ºC</strong></p>
</td>
</tr>
<tr>
<td width="91" align="center" valign="middle">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px"><strong>Servicio permanente</strong></p>
</td>
<td width="97" align="center" valign="middle">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px"><strong>Cortocircuito</strong></p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px"><strong>t ≤ 5s</strong></p>
</td>
</tr>
<tr>
<td width="217" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px"><strong>Policloruro de vinilo (PVC)</strong></p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px"><strong>S ≤ 300 mm<sup>2</sup></strong></p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px"><strong>S &gt; 300 mm<sup>2</sup></strong></p>
</td>
<td width="91" align="center" valign="bottom">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">70</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">70</p>
</td>
<td width="97" align="center" valign="bottom">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">160</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">140</p>
</td>
</tr>
<tr>
<td width="217" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px"><strong>Polietileno reticulado (XLPE)</strong></p>
</td>
<td width="91" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">90</p>
</td>
<td width="97" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">250</p>
</td>
</tr>
<tr>
<td width="217" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px"><strong>Etileno Propileno (EPR)</strong></p>
</td>
<td width="91" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">90</p>
</td>
<td width="97" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">250</p>
</td>
</tr>
</tbody>
</table>
<p>Tabla 2. Cables aislados con aislamiento seco; temperatura máxima, en ºC, asignada al conductor</p>
<p><span id="more-1642"></span></p>
<p>1.1.2. Condiciones de instalación enterrada.</p>
<p>Condiciones tipo de instalación enterrada</p>
<p>A los efectos de determinar la intensidad máxima admisible, se considera la siguiente instalación tipo:Un solo cable tripolar o tetrapolar o un terno de cables unipolares en contacto mutuo, o un cable bipolar o dos cables unipolares en contacto mutuo, directamente enterrados en toda su longitud en una zanja de 0,70 m de profundidad, en un terreno de resistividad térmica media de 1 K.m/W y temperatura ambiente del terreno a dicha profundidad, de 25ºC.</p>
<table style="width: 359px; height: 160px;" border="1" cellspacing="1" cellpadding="8" width="359">
<tbody>
<tr>
<td width="167" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="left"><strong>CABLES</strong></p>
</td>
<td width="190" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="left"><strong>Sección nominal de los conductores (mm<sup>2</sup>)</strong></p>
</td>
<td width="80" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="left"><strong>Intensidad</strong></p>
</td>
</tr>
<tr>
<td width="167" height="154" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="left"><strong>3 x 50 Al + 16 Cu</strong></p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="left"><strong>3 x 95 Al + 30 Cu</strong></p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="left"><strong>3 x 150 Al + 50 Cu</strong></p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="left"><strong>3 x 240 Al + 80 Cu</strong></p>
</td>
<td width="190" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="left">50</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="left">95</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="left">150</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="left">240</p>
</td>
<td width="80" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="left">160</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="left">235</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="left">305</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="left">395</p>
</td>
</tr>
</tbody>
</table>
<p> Tabla 3. Intensidad máxima admisible en amperios para cables tetrapolares con conductores de aluminio y conductor neutro de cobre, en instalación enterrada (servicio permanente).</p>
<p>Temperatura máxima en el conductor: 900C.<br />
Temperatura del terreno: 25ºC.<br />
Profundidad de instalación: 0,70 m.<br />
Resistividad térmica del terreno: 1 K.m/W</p>
<table border="1" width="360">
<tbody>
<tr>
<td rowspan="4" width="14%" align="center"><strong>SECCIÓN NOMINAL mm<sup>2</sup></strong></td>
<td colspan="3" width="42%" align="center"><strong>Terna de cables unipolares (1)(2)</strong></td>
<td colspan="3" width="44%" align="center"><strong>1 cable tripolar o tetrapolar (3)</strong></td>
</tr>
<tr>
<td colspan="3" width="42%" align="center"><strong><a href="http://www.electricasas.com/wp-content/uploads/2008/11/unipolar1.jpg"><img class="alignnone size-medium wp-image-1643" title="unipolar1" src="http://www.electricasas.com/wp-content/uploads/2008/11/unipolar1.jpg" alt="" width="55" height="48" /></a><a href="http://www.electricasas.com/wp-content/uploads/2008/11/unipolar2.jpg"><img class="alignnone size-medium wp-image-1644" title="unipolar2" src="http://www.electricasas.com/wp-content/uploads/2008/11/unipolar2.jpg" alt="" width="75" height="38" /></a></strong></td>
<td colspan="3" width="44%" align="center"><strong><a href="http://www.electricasas.com/wp-content/uploads/2008/11/tripolar.jpg"><img class="alignnone size-medium wp-image-1646" title="tripolar" src="http://www.electricasas.com/wp-content/uploads/2008/11/tripolar.jpg" alt="" width="71" height="68" /></a><a href="http://www.electricasas.com/wp-content/uploads/2008/11/tetrapolar.jpg"><img class="alignnone size-medium wp-image-1645" title="tetrapolar" src="http://www.electricasas.com/wp-content/uploads/2008/11/tetrapolar.jpg" alt="" width="82" height="76" /></a> </strong></td>
</tr>
<tr>
<td colspan="6" width="86%" align="center"><strong>TIPO DE AISLAMIENTO</strong></td>
</tr>
<tr>
<td width="14%" align="center"><strong>XLPE</strong></td>
<td width="14%" align="center"><strong>EPR</strong></td>
<td width="14%" align="center"><strong>PVC</strong></td>
<td width="14%" align="center"><strong>XLPE</strong></td>
<td width="15%" align="center"><strong>EPR</strong></td>
<td width="15%" align="center"><strong>PVC</strong></td>
</tr>
<tr>
<td width="14%" align="center">16<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
500<br />
630</td>
<td width="14%" align="center">97<br />
125<br />
150<br />
180<br />
220<br />
260<br />
295<br />
330<br />
375<br />
430<br />
485<br />
550<br />
615<br />
690</td>
<td width="14%" align="center">94<br />
120<br />
145<br />
175<br />
215<br />
255<br />
290<br />
325<br />
365<br />
420<br />
475<br />
540<br />
605<br />
680</td>
<td width="14%" align="center">86<br />
110<br />
130<br />
155<br />
190<br />
225<br />
260<br />
290<br />
325<br />
380<br />
430<br />
480<br />
525<br />
600</td>
<td width="14%" align="center">90<br />
115<br />
140<br />
165<br />
205<br />
240<br />
275<br />
310<br />
350<br />
405<br />
460<br />
520<br />
-<br />
-</td>
<td width="15%" align="center">86<br />
110<br />
135<br />
160<br />
220<br />
235<br />
270<br />
305<br />
345<br />
395<br />
445<br />
500<br />
-<br />
-</td>
<td width="15%" align="center">76<br />
98<br />
120<br />
140<br />
170<br />
210<br />
235<br />
265<br />
300<br />
350<br />
395<br />
445<br />
-<br />
-</td>
</tr>
</tbody>
</table>
<p>Tabla 4. Intensidad máxima admisible, en amperios, para cables con conductores de aluminio en instalación enterrada (servicio permanente).</p>
<p>Tipo de aislamiento<br />
XLPE &#8211; Polietileno reticulado &#8211; Temperatura máxima en el conductor 90ºC (servicio permanente).<br />
EPR &#8211; Etileno propileno &#8211; Temperatura máxima en el conductor 90ºC (servicio permanente).<br />
PVC &#8211; Policloruro de vinilo &#8211; Temperatura máxima en el conductor 70ºC (servicio permanente).</p>
<p>Temperatura del terreno 25ºC.<br />
Profundidad de instalación 0,70 m.<br />
Resistividad térmica del terreno 1 K.m /W</p>
<p>(1) Incluye el conductor neutro, si existe.<br />
(2) Para el caso de dos cables unipolares, la intensidad máxima admisible será la correspondiente a la columna de la terna de cables unipolares de la misma sección y tipo de aislamiento, multiplicada por 1,225.<br />
(3) Para el caso de un cable bipolar, la intensidad máxima admisible será la correspondiente a la columna del cable tripolar o tetrapolar de la misma sección y tipo de aislamiento , multiplicada 1,225.</p>
<table border="1" width="360">
<tbody>
<tr>
<td rowspan="4" width="14%" align="center"><strong>SECCIÓN NOMINAL mm<sup>2</sup></strong></td>
<td colspan="3" width="42%" align="center"><strong>Terna de cables unipolares (1)(2)</strong></td>
<td colspan="3" width="44%" align="center"><strong>1 cable tripolar o tetrapolar (3)</strong></td>
</tr>
<tr>
<td colspan="3" width="42%" align="center"> <a href="http://www.electricasas.com/wp-content/uploads/2008/11/unipolar1.jpg"><img class="alignnone size-medium wp-image-1643" title="unipolar1" src="http://www.electricasas.com/wp-content/uploads/2008/11/unipolar1.jpg" alt="" width="55" height="48" /></a><a href="http://www.electricasas.com/wp-content/uploads/2008/11/unipolar2.jpg"><img class="alignnone size-medium wp-image-1644" title="unipolar2" src="http://www.electricasas.com/wp-content/uploads/2008/11/unipolar2.jpg" alt="" width="75" height="38" /></a></td>
<td colspan="3" width="44%" align="center"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/tripolar.jpg"><img class="alignnone size-medium wp-image-1646" title="tripolar" src="http://www.electricasas.com/wp-content/uploads/2008/11/tripolar.jpg" alt="" width="71" height="68" /></a><a href="http://www.electricasas.com/wp-content/uploads/2008/11/tetrapolar.jpg"><img class="alignnone size-medium wp-image-1645" title="tetrapolar" src="http://www.electricasas.com/wp-content/uploads/2008/11/tetrapolar.jpg" alt="" width="82" height="76" /></a></td>
</tr>
<tr>
<td colspan="6" width="86%" align="center"><strong>TIPO DE AISLAMIENTO</strong></td>
</tr>
<tr>
<td width="14%" align="center"><strong>XLPE</strong></td>
<td width="14%" align="center"><strong>EPR</strong></td>
<td width="14%" align="center"><strong>PVC</strong></td>
<td width="14%" align="center"><strong>XLPE</strong></td>
<td width="15%" align="center"><strong>EPR</strong></td>
<td width="15%" align="center"><strong>PVC</strong></td>
</tr>
<tr>
<td width="14%" align="center">6<br />
10<br />
16<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
500<br />
630</td>
<td width="14%" align="center">72<br />
96<br />
125<br />
160<br />
190<br />
230<br />
280<br />
325<br />
380<br />
425<br />
480<br />
550<br />
620<br />
705<br />
790<br />
885</td>
<td width="14%" align="center">70<br />
94<br />
120<br />
155<br />
185<br />
225<br />
270<br />
325<br />
372<br />
415<br />
470<br />
540<br />
610<br />
690<br />
775<br />
870</td>
<td width="14%" align="center">63<br />
85<br />
110<br />
140<br />
170<br />
200<br />
245<br />
290<br />
335<br />
370<br />
420<br />
485<br />
550<br />
615<br />
685<br />
770</td>
<td width="14%" align="center">66<br />
88<br />
115<br />
150<br />
180<br />
215<br />
260<br />
310<br />
355<br />
400<br />
450<br />
520<br />
590<br />
665<br />
-<br />
-</td>
<td width="15%" align="center">64<br />
85<br />
110<br />
140<br />
175<br />
205<br />
250<br />
305<br />
350<br />
390<br />
440<br />
505<br />
565<br />
645<br />
-<br />
-</td>
<td width="15%" align="center">56<br />
75<br />
97<br />
125<br />
150<br />
180<br />
220<br />
265<br />
305<br />
340<br />
385<br />
445<br />
505<br />
570<br />
-<br />
-</td>
</tr>
</tbody>
</table>
<p>Tabla 5. Intensidad máxima admisible, en amperios, para cables con conductores de cobre en instalación enterrada (servicio permanente).</p>
<p>Tipo de aislamiento<br />
XLPE &#8211; Polietileno reticulado &#8211; Temperatura máxima en el conductor 90ºC (servicio permanente).<br />
EPR &#8211; Etileno propileno &#8211; Temperatura máxima en el conductor 90ºC (servicio permanente).<br />
PVC &#8211; Policloruro de vinilo &#8211; Temperatura máxima en el conductor 70ºC (servicio permanente).</p>
<p>Temperatura del terreno 25ºC.<br />
Profundidad de instalación 0,70 m.<br />
Resistividad térmica del terreno 1 K.m /W</p>
<p>(1) Incluye el conductor neutro, si existe.<br />
(2) Para el caso de dos cables unipolares, la intensidad máxima admisible será la correspondiente a la columna de la terna de cables unipolares de la misma sección y tipo de aislamiento, multiplicada por 1,225.<br />
(3) Para el caso de un cable bipolar, la intensidad máxima admisible será la correspondiente a la columna del cable tripolar o tetrapolar de la misma sección y tipo de aislamiento , multiplicada 1,225.</p>
<p>1.1.2.2. Condiciones especiales de instalación enterrada y factores de corrección de intensidad admisible.</p>
<p>La intensidad admisible de un cable, determinada por las condiciones de instalación enterrada, deberán corregirse teniendo en cuenta cada una de las magnitudes de la instalación real que difieran de aquellas, de forma que el aumento de temperatura provocado por la circulación de la intensidad calculada, no dé lugar a una temperatura en el conductor superior a la prescrita en la tabla 2. A continuación se exponen algunos casos particulares de instalación, cuyas características afectan al valor máximo de la intensidad admisible, indicando los factores de corrección a aplicar.</p>
<p>1.1.2.2.1.Cables enterrados en terrenos cuya temperatura sea distinta de 25ºC.</p>
<p>En la tabla 6 se indican los factores de corrección, F, de la intensidad admisible para temperaturas del terreno θt, distintas de 25ºC, en función de la temperatura máxima de servicio θs , de la tabla 2.</p>
<table border="1" width="389">
<tbody>
<tr>
<td rowspan="2" width="21%" height="44" align="center" valign="middle"><strong>Temperatura de servicio θ<sub>s </sub>(ºC)</strong></td>
<td colspan="9" width="79%" height="44" align="center" valign="top"><strong>Temperatura del terreno, θ<sub>t</sub> ,en ºC</strong></td>
</tr>
<tr>
<td width="8%" height="24" align="center" valign="top"><strong>10</strong></td>
<td width="9%" height="24" align="center" valign="top"><strong>15</strong></td>
<td width="9%" height="24" align="center" valign="top"><strong>20</strong></td>
<td width="9%" height="24" align="center" valign="top"><strong>25</strong></td>
<td width="9%" height="24" align="center" valign="top"><strong>30</strong></td>
</tr>
<tr>
<td width="21%" height="24" align="center" valign="top"><strong>90</strong></td>
<td width="8%" height="24" align="center" valign="top">1.11</td>
<td width="9%" height="24" align="center" valign="top">1.07</td>
<td width="9%" height="24" align="center" valign="top">1.04</td>
<td width="9%" height="24" align="center" valign="top">1</td>
<td width="9%" height="24" align="center" valign="top">0.96</td>
</tr>
<tr>
<td width="21%" height="25" align="center" valign="top"><strong>70</strong></td>
<td width="8%" height="25" align="center" valign="top">1.15</td>
<td width="9%" height="25" align="center" valign="top">1.11</td>
<td width="9%" height="25" align="center" valign="top">1.05</td>
<td width="9%" height="25" align="center" valign="top">1</td>
<td width="9%" height="25" align="center" valign="top">0.94</td>
</tr>
</tbody>
</table>
<p> </p>
<table border="1" width="389">
<tbody>
<tr>
<td rowspan="2" width="21%" height="44" align="center" valign="middle"><strong>Temperatura de servicio θ<sub>s </sub>(ºC)</strong></td>
<td colspan="11" width="79%" height="44" align="center" valign="top"><strong>Temperatura del terreno, θ<sub>t</sub> ,en ºC</strong></td>
</tr>
<tr>
<td width="9%" height="24" align="center" valign="top"><strong>35</strong></td>
<td width="9%" height="24" align="center" valign="top"><strong>40</strong></td>
<td width="9%" height="24" align="center" valign="top"><strong>45</strong></td>
<td width="9%" height="24" align="center" valign="top"><strong>50</strong></td>
<td width="9%" height="24" align="center" valign="top"><strong> </strong></td>
</tr>
<tr>
<td width="21%" height="24" align="center" valign="top"><strong>90</strong></td>
<td width="9%" height="24" align="center" valign="top">0.92</td>
<td width="9%" height="24" align="center" valign="top">0.88</td>
<td width="9%" height="24" align="center" valign="top">0.83</td>
<td width="9%" height="24" align="center" valign="top">0.78</td>
<td width="9%" height="24" align="center" valign="top"><strong> </strong></td>
</tr>
<tr>
<td width="21%" height="25" align="center" valign="top"><strong>70</strong></td>
<td width="9%" height="25" align="center" valign="top">0.88</td>
<td width="9%" height="25" align="center" valign="top">0.82</td>
<td width="9%" height="25" align="center" valign="top">0.75</td>
<td width="9%" height="25" align="center" valign="top">0.67</td>
</tr>
</tbody>
</table>
<p>Tabla 6. Factor de corrección F, para temperatura del terreno distinto de 25ºC</p>
<p>El factor de corrección para otras temperaturas del terreno, distintas de las de la tabla, será:</p>
<p style="TEXT-ALIGN: center"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/itc_bt_07_5.gif"><img class="size-full wp-image-1647 aligncenter" title="itc_bt_07_5" src="http://www.electricasas.com/wp-content/uploads/2008/11/itc_bt_07_5.gif" alt="" width="87" height="49" /></a></p>
<p style="TEXT-ALIGN: left">1.1.2.2.2. Cables enterrados, directamente o en conducciones, en terreno de resistividad térmica distinta de 1 K. m/W.</p>
<p style="TEXT-ALIGN: left">En la tabla 7 se indican, para distintas resistividades térmicas del terreno, los correspondientes factores de corrección de la intensidad admisible.</p>
<p style="TEXT-ALIGN: left">
<table border="1" width="360">
<tbody>
<tr>
<td rowspan="2" width="79" align="center" valign="top"><strong>Tipo de</strong> <strong>cable</strong></td>
<td colspan="11" align="center" valign="top"><strong>Resistividad térmica del terreno, en K.m/W</strong></td>
</tr>
<tr>
<td valign="top"><strong>0.80</strong></td>
<td valign="top"><strong>0.85</strong></td>
<td valign="top"><strong>0.90</strong></td>
<td valign="top"><strong>1</strong></td>
<td valign="top"><strong>1.10</strong></td>
<td valign="top&lt;B"><strong>1.20</strong></td>
</tr>
<tr>
<td valign="top"><strong>Unipolar</strong></td>
<td valign="top">1.09</td>
<td valign="top">1.06</td>
<td valign="top">1.04</td>
<td valign="top">1</td>
<td valign="top">0.96</td>
<td valign="top">0.93</td>
</tr>
<tr>
<td height="30" valign="top"><strong>Tripolar</strong></td>
<td valign="top">1.07</td>
<td valign="top">1.05</td>
<td valign="top">1.03</td>
<td valign="top">1</td>
<td valign="top">0.97</td>
<td valign="top">0.94</td>
</tr>
</tbody>
</table>
<p align="center"> </p>
<div style="TEXT-ALIGN: left">
<table border="1" width="360">
<tbody>
<tr>
<td rowspan="2" width="79" align="center" valign="top"><strong>Tipo de</strong> <strong>cable</strong></td>
<td colspan="11" align="center" valign="top"><strong>Resistividad térmica del terreno, en K.m/W</strong></td>
</tr>
<tr>
<td valign="top"><strong>1.40</strong></td>
<td valign="top"><strong>1.65</strong></td>
<td valign="top"><strong>2.00</strong></td>
<td valign="top"><strong>2.50</strong></td>
<td valign="top"><strong>2.80</strong></td>
<td valign="top"><strong></strong></td>
</tr>
<tr>
<td><strong>Unipolar</strong></td>
<td valign="top">0.87</td>
<td valign="top">0.81</td>
<td valign="top">0.75</td>
<td valign="top">0.68</td>
<td valign="top">0.66</td>
<td> </td>
</tr>
<tr>
<td><strong>Tripolar</strong></td>
<td valign="top">0.89</td>
<td valign="top">0.84</td>
<td valign="top">0.78</td>
<td valign="top">0.71</td>
<td valign="top">0.69</td>
<td> </td>
</tr>
</tbody>
</table>
</div>
<p>Tabla 7. Factor de corrección para resistividad térmica del terreno distinta de 1 K. m/W.</p>
<p>1.1.2.2.3. Cables tripolares o tetrapolares o ternos de cables unipolares agrupados bajo tierra.</p>
<p>En la tabla 8 se indican los factores de corrección que se deben aplicar, según el número de cables tripolares o ternos de unipolares y la distancia entre ellos.</p>
<table border="1">
<tbody>
<tr>
<td colspan="9" height="30" align="center" valign="top"><strong>Factor de corrección</strong></td>
</tr>
<tr>
<td width="103" align="center" valign="middle"><strong>Separación entre los cables o ternos</strong></td>
<td colspan="8" align="center" valign="middle"><strong>Número de cables o ternos de la zanja</strong></td>
</tr>
<tr>
<td width="103" align="center" valign="middle"> </td>
<td width="63" align="center" valign="top"><strong>2</strong></td>
<td width="48" align="center" valign="top"><strong>3</strong></td>
<td width="48" align="center" valign="top"><strong>4</strong></td>
<td width="48" align="center" valign="top"><strong>5</strong></td>
<td width="48" align="center" valign="top"><strong>6</strong></td>
<td width="48" align="center" valign="top"><strong>8</strong></td>
<td width="48" align="center" valign="top"><strong>10</strong></td>
<td width="49" align="center" valign="top"><strong>12</strong></td>
</tr>
<tr>
<td width="103" height="30" align="center" valign="top"><strong>D=0 (en contacto)</strong></td>
<td width="63" height="30" align="center" valign="top">0,80</td>
<td width="48" height="30" align="center" valign="top">0,70</td>
<td width="48" height="30" align="center" valign="top">0,64</td>
<td width="48" height="30" align="center" valign="top">0,60</td>
<td width="48" height="30" align="center" valign="top">0,56</td>
<td width="48" height="30" align="center" valign="top">0,53</td>
<td width="48" height="30" align="center" valign="top">0,50</td>
<td width="49" height="30" align="center" valign="top">0,47</td>
</tr>
<tr>
<td width="103" align="center" valign="top"><strong>d= 0,07 m</strong></td>
<td width="63" align="center" valign="top">0,85</td>
<td width="48" align="center" valign="top">0,75</td>
<td width="48" align="center" valign="top">0,68</td>
<td width="48" align="center" valign="top">0,64</td>
<td width="48" align="center" valign="top">0,6</td>
<td width="48" align="center" valign="top">0,56</td>
<td width="48" align="center" valign="top">0,53</td>
<td width="49" align="center" valign="top">0,50</td>
</tr>
<tr>
<td width="103" align="center" valign="top"><strong>d= 0,10 m</strong></td>
<td width="63" align="center" valign="top">0,85</td>
<td width="48" align="center" valign="top">0,76</td>
<td width="48" align="center" valign="top">0,69</td>
<td width="48" align="center" valign="top">0,65</td>
<td width="48" align="center" valign="top">0,62</td>
<td width="48" align="center" valign="top">0,58</td>
<td width="48" align="center" valign="top">0,55</td>
<td width="49" align="center" valign="top">0,53</td>
</tr>
<tr>
<td width="103" align="center" valign="top"><strong>d= 0,15 m</strong></td>
<td width="63" align="center" valign="top">0,87</td>
<td width="48" align="center" valign="top">0,77</td>
<td width="48" align="center" valign="top">0,72</td>
<td width="48" align="center" valign="top">0,68</td>
<td width="48" align="center" valign="top">0,66</td>
<td width="48" align="center" valign="top">0,62</td>
<td width="48" align="center" valign="top">0,59</td>
<td width="49" align="center" valign="top">0,57</td>
</tr>
<tr>
<td width="103" align="center" valign="top"><strong>d= 0,20 m</strong></td>
<td width="63" align="center" valign="top">0,88</td>
<td width="48" align="center" valign="top">0,79</td>
<td width="48" align="center" valign="top">0,74</td>
<td width="48" align="center" valign="top">0,70</td>
<td width="48" align="center" valign="top">0,68</td>
<td width="48" align="center" valign="top">0,64</td>
<td width="48" align="center" valign="top">0,62</td>
<td width="49" align="center" valign="top">0,60</td>
</tr>
<tr>
<td width="103" align="center" valign="top"><strong>d= 0,25 m</strong></td>
<td width="63" align="center" valign="top">0,89</td>
<td width="48" align="center" valign="top">0,80</td>
<td width="48" align="center" valign="top">0,76</td>
<td width="48" align="center" valign="top">0,72</td>
<td width="48" align="center" valign="top">0,70</td>
<td width="48" align="center" valign="top">0,66</td>
<td width="48" align="center" valign="top">0,64</td>
<td width="49" align="center" valign="top">0,62</td>
</tr>
</tbody>
</table>
<p>Tabla 8. Factor de corrección para agrupaciones de cables trifásicos o ternos de cables unipolares</p>
<p style="TEXT-ALIGN: center"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/itc_bt_07_1.jpg"><img class="size-full wp-image-1648 aligncenter" title="itc_bt_07_1" src="http://www.electricasas.com/wp-content/uploads/2008/11/itc_bt_07_1.jpg" alt="" width="397" height="204" /></a></p>
<p>1.1.2.2.4. Cables enterrados en zanja a diferentes profundidades.</p>
<p>En la tabla 9 se indican los factores de corrección que deben aplicarse para profundidades de instalación distintas de 0,70 m.</p>
<table border="1" cellspacing="1" cellpadding="4">
<tbody>
<tr>
<td width="128" align="center" valign="middle"><strong>Profundidad de instalación (m)</strong></td>
<td width="31" align="center" valign="middle">0,4</td>
<td width="37" align="center" valign="middle">0,5</td>
<td width="32" align="center" valign="middle">0,6</td>
<td width="36" align="center" valign="middle">0,7</td>
<td width="37" align="center" valign="middle">0,80</td>
<td width="37" align="center" valign="middle">0,90</td>
<td width="37" align="center" valign="middle">1,00</td>
<td width="32" align="center" valign="middle">1,20</td>
</tr>
<tr>
<td width="128" align="center" valign="middle"><strong>Factor de corrección</strong></td>
<td width="31" align="center" valign="middle">1,03</td>
<td width="37" align="center" valign="middle">1,02</td>
<td width="32" align="center" valign="middle">1,01</td>
<td width="36" align="center" valign="middle">1</td>
<td width="37" align="center" valign="middle">0,90</td>
<td width="37" align="center" valign="middle">0,98</td>
<td width="37" align="center" valign="middle">0,97</td>
<td width="32" align="center" valign="middle">0,95</td>
</tr>
</tbody>
</table>
<p>Tabla 9. Factores de corrección para diferentes profundidades de instalación</p>
<p>1.1.3. Cables enterrados en zanja en el interior de tubos o similares.</p>
<p>En este tipo de instalaciones es de aplicación todo lo establecido en el apartado 1.1.2., además de lo indicado a continuación.</p>
<p>Se instalará un circuito por tubo. La relación entre el diámetro interior del tubo y el diámetro aparente del circuito será superior a 2, pudiéndose aceptar excepcionalmente 1,5.</p>
<p>En el caso de una línea con cable tripolar o con un terno de cables unipolares en el interior de un mismo tubo, se aplicará un factor de corrección de 0,8.</p>
<p>Si se trata de una línea con cuatro cables unipolares situados en sendos tubos, podrá aplicarse un factor de corrección de 0,9.</p>
<p>Si se trata de una agrupación de tubos, el factor dependerá del tipo de agrupación y variará para cada cable según esté colocado en un tubo central o periférico. Cada caso deberá estudiarse individualmente.</p>
<p>En el caso de canalizaciones bajo tubos que no superen los 15 m., si el tubo se rellena con aglomerados especiales no será necesario aplicar factor de corrección de intensidad por este motivo.</p>
<p>1.1.4. Condiciones de instalación al aire (en galerías, zanjas registrables, atarjeas o canales revisables).</p>
<p>1.1.4.1. Condiciones tipo de instalación al aire (en galerías, zanjas registrables, etc.).</p>
<p>A los efectos de determinar la intensidad máxima admisible, se considera la siguiente instalación tipo:</p>
<p>Un solo cable tripolar o tetrapolar o un terno de cables unipolares en contacto mutuo, con una colocación tal que permita una eficaz renovación del aire, siendo la temperatura del medio ambiente de 40ºC. Por ejemplo, con el cable colocado sobre bandejas o fijado a una pared, etc..</p>
<table border="1" cellspacing="1" cellpadding="8">
<tbody>
<tr>
<td width="130" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px"><strong>Cables</strong></p>
</td>
<td width="186" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px"><strong>Sección nominal de los conductores (mm<sup>2</sup>)</strong></p>
</td>
<td width="103" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px"><strong>Intensidad</strong></p>
</td>
</tr>
<tr>
<td width="130" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">3 x 50 Al + 16 Cu</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">3 x 95 Al + 30 Cu</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">3 x 150 Al + 50 Cu</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">3 x 240 Al + 80 Cu</p>
</td>
<td width="186" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px" align="center">50</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">95</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">150</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">240</p>
</td>
<td width="103" align="center" valign="top">
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">125</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">195</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">260</p>
<p style="MARGIN-TOP: 0px; MARGIN-BOTTOM: 0px">360</p>
</td>
</tr>
</tbody>
</table>
<p>Tabla 10. Intensidad máxima admisible, en amperios, en servicio permanente, para cables tetrapolares con conductores de aluminio y con conductor neutro de cobre, en instalación al aire en galerías ventiladas.</p>
<p>Temperatura máxima en el conductor: 90ºC.<br />
Temperatura del aire ambiente: 40ºC.<br />
Disposición que permita una eficaz renovación del aire.</p>
<table style="height: 378px;" border="1" width="357">
<tbody>
<tr>
<td rowspan="4" width="52" align="center"><strong>Sección nominal mm<sup>2</sup></strong></td>
<td colspan="3" align="center"><strong>Tres cables unipolares (1)</strong></td>
<td colspan="3" align="center"><strong>1 cable trifásico</strong></td>
</tr>
<tr>
<td colspan="3" align="center"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/unipolar1.jpg"><img class="alignnone size-medium wp-image-1643" title="unipolar1" src="http://www.electricasas.com/wp-content/uploads/2008/11/unipolar1.jpg" alt="" width="55" height="48" /></a></td>
<td colspan="3" align="center"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/tripolar.jpg"><img class="alignnone size-medium wp-image-1646" title="tripolar" src="http://www.electricasas.com/wp-content/uploads/2008/11/tripolar.jpg" alt="" width="71" height="68" /></a><a href="http://www.electricasas.com/wp-content/uploads/2008/11/tetrapolar.jpg"><img class="alignnone size-medium wp-image-1645" title="tetrapolar" src="http://www.electricasas.com/wp-content/uploads/2008/11/tetrapolar.jpg" alt="" width="82" height="76" /></a></td>
</tr>
<tr>
<td colspan="6" align="center"><strong>TIPO DE AISLAMIENTO</strong></td>
</tr>
<tr>
<td width="43" align="center"><strong>XLPE</strong></td>
<td width="34" align="center"><strong>EPR</strong></td>
<td width="37" align="center"><strong>PVC</strong></td>
<td width="33" align="center"><strong>XLPE</strong></td>
<td width="26" align="center"><strong>EPR</strong></td>
<td width="100" align="center"><strong>PVC</strong></td>
</tr>
<tr>
<td align="center">16<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
500<br />
630</td>
<td align="center">67<br />
93<br />
115<br />
140<br />
180<br />
220<br />
260<br />
300<br />
350<br />
420<br />
480<br />
550<br />
645<br />
740</td>
<td align="center">65<br />
90<br />
110<br />
135<br />
175<br />
215<br />
255<br />
290<br />
345<br />
400<br />
465<br />
545<br />
625<br />
715</td>
<td align="center">55<br />
75<br />
90<br />
115<br />
145<br />
180<br />
215<br />
245<br />
285<br />
340<br />
390<br />
455<br />
520<br />
600</td>
<td align="center">64<br />
85<br />
105<br />
130<br />
165<br />
205<br />
235<br />
275<br />
315<br />
370<br />
425<br />
505<br />
-<br />
-</td>
<td align="center">63<br />
82<br />
100<br />
125<br />
155<br />
195<br />
225<br />
260<br />
300<br />
360<br />
405<br />
475<br />
-<br />
-</td>
<td align="center">51<br />
68<br />
82<br />
100<br />
130<br />
160<br />
185<br />
215<br />
245<br />
290<br />
335<br />
385<br />
-<br />
-</td>
</tr>
</tbody>
</table>
<p>Tabla 11. Intensidad máxima admisible, en amperios, en servicio permanente para cables con conductores de aluminio en instalación al aire en galerías ventiladas (temperatura ambiente 40ºC)</p>
<p>Temperatura del aire 40ºC.<br />
Un cable trifásico al aire o un conjunto (terna) de cables unipolares en contacto mutuo.<br />
Disposición que permita una eficaz renovación del aire.<br />
(1) Incluye el conductor neutro, si existiese.</p>
<table border="1" width="345">
<tbody>
<tr>
<td rowspan="4" width="14%" height="83" align="center"><strong>Sección nominal mm<sup>2</sup></strong></td>
<td colspan="3" width="42%" height="16" align="center"><strong>Tres cables unipolares (1)</strong></td>
<td colspan="3" width="44%" height="16" align="center"><strong>1 cable trifásico</strong></td>
</tr>
<tr>
<td colspan="3" width="42%" height="16" align="center"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/unipolar1.jpg"><img class="alignnone size-medium wp-image-1643" title="unipolar1" src="http://www.electricasas.com/wp-content/uploads/2008/11/unipolar1.jpg" alt="" width="55" height="48" /></a></td>
<td colspan="3" width="44%" height="16" align="center"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/tripolar.jpg"><img class="alignnone size-medium wp-image-1646" title="tripolar" src="http://www.electricasas.com/wp-content/uploads/2008/11/tripolar.jpg" alt="" width="71" height="68" /></a><a href="http://www.electricasas.com/wp-content/uploads/2008/11/tetrapolar.jpg"><img class="alignnone size-medium wp-image-1645" title="tetrapolar" src="http://www.electricasas.com/wp-content/uploads/2008/11/tetrapolar.jpg" alt="" width="82" height="76" /></a></td>
</tr>
<tr>
<td colspan="6" width="86%" height="16" align="center"><strong>TIPO DE AISLAMIENTO</strong></td>
</tr>
<tr>
<td width="14%" height="17" align="center"><strong>XLPE</strong></td>
<td width="14%" height="17" align="center"><strong>EPR</strong></td>
<td width="14%" height="17" align="center"><strong>PVC</strong></td>
<td width="14%" height="17" align="center"><strong>XLPE</strong></td>
<td width="15%" height="17" align="center"><strong>EPR</strong></td>
<td width="15%" height="17" align="center"><strong>PVC</strong></td>
</tr>
<tr>
<td width="14%" height="245" align="center">6<br />
10<br />
16<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
500<br />
630</td>
<td width="14%" height="245" align="center"> 46<br />
64<br />
86<br />
120<br />
145<br />
180<br />
230<br />
285<br />
335<br />
385<br />
450<br />
535<br />
615<br />
720<br />
825<br />
950</td>
<td width="14%" height="245" align="center">45<br />
62<br />
83<br />
115<br />
140<br />
175<br />
225<br />
280<br />
325<br />
375<br />
449<br />
515<br />
595<br />
700<br />
800<br />
915</td>
<td width="14%" height="245" align="center">38<br />
53<br />
71<br />
96<br />
115<br />
145<br />
185<br />
235<br />
275<br />
315<br />
365<br />
435<br />
500<br />
585<br />
665<br />
765</td>
<td width="14%" height="245" align="center">44<br />
61<br />
82<br />
110<br />
135<br />
165<br />
210<br />
260<br />
300<br />
350<br />
400<br />
475<br />
545<br />
645<br />
-<br />
-</td>
<td width="15%" height="245" align="center"> 43<br />
60<br />
80<br />
105<br />
130<br />
160<br />
220<br />
250<br />
290<br />
335<br />
385<br />
460<br />
520<br />
610<br />
-<br />
-</td>
<td width="15%" height="245" align="center"> 36<br />
50<br />
65<br />
87<br />
105<br />
130<br />
165<br />
205<br />
240<br />
275<br />
315<br />
370<br />
425<br />
495<br />
-<br />
-</td>
</tr>
</tbody>
</table>
<p>Tabla 12. Intensidad máxima admisible, en amperios, en servicio permanente para cables con conductores de cobre en instalación al aire en galerías ventiladas (temperatura ambiente 40ºC)</p>
<p>Temperatura del aire 40ºC. Un cable trifásico al aire o un conjunto (terna) de cables unipolares en contacto mutuo.<br />
Disposición que permita una eficaz renovación del aire.<br />
(1) Incluye el conductor neutro, si existiese.</p>
<p>1.1.4.2. Condiciones especiales de instalación al aire en galerías ventiladas y factores de corrección de la intensidad admisible.</p>
<p>La intensidad admisible de un cable, determinada por las condiciones de instalación al aire en galerías ventiladas cuyas características se han especificado en el apartado 3.1.4.1., deberá corregirse teniendo en cuenta cada una de las magnitudes de la instalación real que difieran de aquellas, de forma que el aumento de temperatura provocado por la circulación de la intensidad calculada no de lugar a una temperatura en el conductor, superior a la prescrita en la tabla 2. A continuación, se exponen algunos casos particulares de instalación, cuyas características afectan al valor máximo de la intensidad admisible, indicando los coeficientes de corrección a aplicar.</p>
<p>1.1.4.2.1. Cables instalados al aire en ambientes de temperatura distinta de 40ºC.</p>
<p>En la tabla 13 se indican los factores de corrección F, de la intensidad admisible para temperaturas del aire ambiente, θa, distintas de 40ºC, en función de la temperatura máxima de servicio θs en la tabla 2.<br />
 </p>
<table border="1" width="393">
<tbody>
<tr>
<td rowspan="2" width="77" height="69" align="center" valign="top"><strong>Temperatura de servicio θ<sub>s</sub> en ºC</strong></td>
<td colspan="11" height="28" align="center" valign="top"><strong>Temperatura ambiente, θ<sub>a</sub>, en ºC</strong></td>
</tr>
<tr>
<td width="48" height="29" align="center" valign="top"><strong>10</strong></td>
<td width="48" height="29" align="center" valign="top"><strong>15</strong></td>
<td width="48" height="29" align="center" valign="top"><strong>20</strong></td>
<td width="48" height="29" align="center" valign="top"><strong>25</strong></td>
<td width="84" height="29" align="center" valign="top"><strong>30</strong></td>
</tr>
<tr>
<td width="77" height="29" align="center" valign="top"><strong>90</strong></td>
<td width="48" height="29" align="center" valign="top">1.27</td>
<td width="48" height="29" align="center" valign="top">1.22</td>
<td width="48" height="29" align="center" valign="top">1.18</td>
<td width="48" height="29" align="center" valign="top">1.14</td>
<td width="84" height="29" align="center" valign="top">1.10</td>
</tr>
<tr>
<td width="77" height="31" align="center" valign="top"><strong>70</strong></td>
<td width="48" height="31" align="center" valign="top">1.41</td>
<td width="48" height="31" align="center" valign="top">1.35</td>
<td width="48" height="31" align="center" valign="top">1.29</td>
<td width="48" height="31" align="center" valign="top">1.22</td>
<td width="84" height="31" align="center" valign="top">1.15</td>
</tr>
</tbody>
</table>
<p align="center"> </p>
<div style="text-align: left;">
<table border="1" width="360">
<tbody>
<tr>
<td rowspan="2" width="77" height="69" align="center" valign="top"><strong>Temperatura de servicio θ<sub>s</sub> en ºC</strong></td>
<td colspan="11" height="28" align="center" valign="top"><strong>Temperatura ambiente, θ<sub>a</sub>, en ºC</strong></td>
</tr>
<tr>
<td width="48" height="29" align="center" valign="top"><strong>35</strong></td>
<td width="31" height="29" align="center" valign="top"><strong>40</strong></td>
<td width="48" height="29" align="center" valign="top"><strong>45</strong></td>
<td width="48" height="29" align="center" valign="top"><strong>50</strong></td>
<td width="48" height="29" align="center" valign="top"><strong>55</strong></td>
<td width="48" height="29" align="center" valign="top"><strong>60</strong></td>
</tr>
<tr>
<td width="77" height="29" align="center" valign="top"><strong>90</strong></td>
<td width="48" height="29" align="center" valign="top">1.05</td>
<td width="31" height="29" align="center" valign="top">1</td>
<td width="48" height="29" align="center" valign="top">0.95</td>
<td width="48" height="29" align="center" valign="top">0.90</td>
<td width="48" height="29" align="center" valign="top">0.84</td>
<td width="48" height="29" align="center" valign="top">0.77</td>
</tr>
<tr>
<td width="77" height="31" align="center" valign="top"><strong>70</strong></td>
<td width="48" height="31" align="center" valign="top">1.08</td>
<td width="31" height="31" align="center" valign="top">1</td>
<td width="48" height="31" align="center" valign="top">0.91</td>
<td width="48" height="31" align="center" valign="top">0.81</td>
<td width="48" height="31" align="center" valign="top">0.71</td>
<td width="48" height="31" align="center" valign="top">0.58</td>
</tr>
</tbody>
</table>
</div>
<p>Tabla 13. Coeficiente de corrección F para temperatura ambiente distinta de 40ºC</p>
<p>El factor de corrección para otras temperaturas, distintas de las de la tabla, será:</p>
<p style="text-align: center;"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/itc_bt_07_6.gif"><img class="size-full wp-image-1649 aligncenter" title="itc_bt_07_6" src="http://www.electricasas.com/wp-content/uploads/2008/11/itc_bt_07_6.gif" alt="" width="90" height="48" /></a></p>
<p>1.1.4.2.2. Cables instalados al aire en canales o galerías pequeñas.</p>
<p>Se observa que en ciertas condiciones de instalación (en canalillos, galerías pequeñas, etc&#8230;), en los que no hay una eficaz renovación de aire, el calor disipado por los cables no puede difundirse libremente y provoca un aumento de la temperatura del aire.</p>
<p>La magnitud de este aumento depende de muchos factores y debe ser determinada en cada caso como una estimación aproximada. Debe tenerse en cuenta que el incremento de temperatura por este motivo puede ser del orden de 15 K. La intensidad admisible en las condiciones de régimen deberá, por tanto, reducirse con los coeficientes de la tabla 13.</p>
<p>1.1.4.2.3. Grupos de cables instalados al aire.</p>
<p>En las tablas 14 y 15 se dan los factores de corrección a aplicar en los agrupamientos de varios circuitos constituidos por cables unipolares o multipolares en función del tipo de instalación y número de circuitos.</p>
<table border="1" width="457">
<tbody>
<tr>
<td colspan="2" rowspan="2" width="28%" align="center"><strong>Tipo de instalación</strong></td>
<td rowspan="2" width="14%" align="center"><strong>Nº de bandejas</strong></td>
<td colspan="3" width="43%" align="center"><strong>Nº de circuitos trifásicos (2)</strong></td>
<td rowspan="2" width="15%" align="center"><strong>A utilizar para (1)</strong></td>
</tr>
<tr>
<td width="15%" align="center"><strong>1</strong></td>
<td width="14%" align="center"><strong>2</strong></td>
<td width="14%" align="center"><strong>3</strong></td>
</tr>
<tr>
<td rowspan="3" width="14%" align="center">Bandejas perforadas (3)</td>
<td rowspan="3" width="14%" align="center"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt1.gif"><img class="alignnone size-medium wp-image-1650" title="itc-bt1" src="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt1.gif" alt="" width="144" height="76" /></a></td>
<td width="14%" align="center">1</td>
<td width="14%" align="center">0,95</td>
<td width="14%" align="center">0,90</td>
<td width="15%" align="center">0,85</td>
<td rowspan="3" width="15%" align="center">Tres cables en capa horizontal</td>
</tr>
<tr>
<td width="14%" align="center">2</td>
<td width="14%" align="center">0,95</td>
<td width="14%" align="center">0,85</td>
<td width="15%" align="center">0,80</td>
</tr>
<tr>
<td width="14%" align="center">3</td>
<td width="14%" align="center">0,95</td>
<td width="14%" align="center">0,85</td>
<td width="15%" align="center">0,80</td>
</tr>
<tr>
<td rowspan="2" width="14%" align="center">Bandejas verticales perforadas (4)</td>
<td rowspan="2" width="14%" align="center"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt2.gif"><img class="alignnone size-medium wp-image-1651" title="itc-bt2" src="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt2.gif" alt="" width="142" height="86" /></a></td>
<td width="14%" align="center">1</td>
<td width="14%" align="center">0,95</td>
<td width="14%" align="center">0,85</td>
<td width="15%" align="center">-</td>
<td rowspan="2" width="15%" align="center">Tres cables en capa vertical</td>
</tr>
<tr>
<td width="14%" align="center">2</td>
<td width="14%" align="center">0,90</td>
<td width="14%" align="center">0,85</td>
<td width="15%" align="center">-</td>
</tr>
<tr>
<td rowspan="3" width="14%" align="center">Bandejas escalera, soporte, etc. (3)</td>
<td rowspan="3" width="14%" align="center"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt3.gif"><img class="alignnone size-medium wp-image-1652" title="itc-bt3" src="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt3.gif" alt="" width="137" height="78" /></a></td>
<td width="14%" align="center">1</td>
<td width="14%" align="center">1,00</td>
<td width="14%" align="center">0,95</td>
<td width="15%" align="center">0,95</td>
<td rowspan="3" width="15%" align="center">Tres cables en capa horizontal</td>
</tr>
<tr>
<td width="14%" align="center">2</td>
<td width="14%" align="center">0,95</td>
<td width="14%" align="center">0,90</td>
<td width="15%" align="center">0,90</td>
</tr>
<tr>
<td width="14%" align="center">3</td>
<td width="14%" align="center">0,95</td>
<td width="14%" align="center">0,90</td>
<td width="15%" align="center">0,85</td>
</tr>
<tr>
<td rowspan="3" width="14%" align="center">Bandejas perforadas (3)</td>
<td rowspan="3" width="14%" align="center"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt4.gif"><img class="alignnone size-medium wp-image-1653" title="itc-bt4" src="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt4.gif" alt="" width="115" height="72" /></a></td>
<td width="14%" align="center">1</td>
<td width="14%" align="center">1,00</td>
<td width="14%" align="center">1,00</td>
<td width="15%" align="center">0,90</td>
<td rowspan="8" width="15%" align="center">Tres cables dispuestos en trébol</td>
</tr>
<tr>
<td width="14%" align="center">2</td>
<td width="14%" align="center">0,95</td>
<td width="14%" align="center">0,95</td>
<td width="15%" align="center">0,85</td>
</tr>
<tr>
<td width="14%" align="center">3</td>
<td width="14%" align="center">0,95</td>
<td width="14%" align="center">0,90</td>
<td width="15%" align="center">0,90</td>
</tr>
<tr>
<td rowspan="2" width="14%" align="center">Bandejas verticales perforadas (4)</td>
<td rowspan="2" width="14%" align="center"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt5.gif"><img class="alignnone size-medium wp-image-1654" title="itc-bt5" src="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt5.gif" alt="" width="101" height="71" /></a></td>
<td width="14%" align="center">1</td>
<td width="14%" align="center">1,00</td>
<td width="14%" align="center">0,90</td>
<td width="15%" align="center">0,90</td>
</tr>
<tr>
<td width="14%" align="center">2</td>
<td width="14%" align="center">1,00</td>
<td width="14%" align="center">0,90</td>
<td width="15%" align="center">0,85</td>
</tr>
<tr>
<td rowspan="3" width="14%" align="center">Bandejas escalera, soporte, etc. (3)</td>
<td rowspan="3" width="14%" align="center"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt6.gif"><img class="alignnone size-medium wp-image-1655" title="itc-bt6" src="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt6.gif" alt="" width="115" height="77" /></a></td>
<td width="14%" align="center">1</td>
<td width="14%" align="center">1,00</td>
<td width="14%" align="center">1,00</td>
<td width="15%" align="center">1,00</td>
</tr>
<tr>
<td width="14%" align="center">2</td>
<td width="14%" align="center">0,95</td>
<td width="14%" align="center">0,95</td>
<td width="15%" align="center">0,95</td>
</tr>
<tr>
<td width="14%" align="center">3</td>
<td width="14%" align="center">0,95</td>
<td width="14%" align="center">0,95</td>
<td width="15%" align="center">0,90</td>
</tr>
</tbody>
</table>
<p>Tabla 14. Factor de corrección para agrupaciones de cables unipolares instalados al aire</p>
<p>NOTAS:</p>
<p>(1) Incluye además el conductor neutro, si existiese.</p>
<p>(2) Para circuitos con varios cables en paralelo por fase, a los efectos de la aplicación de esta tabla, cada grupo de tres conductores se considera como un circuito.</p>
<p>(3) Los valores están indicados para una distancia vertical entre bandejas de 300 mm. Para distancias más pequeñas, se reducirán los factores.</p>
<p>(4) Los valores están indicados para una distancia horizontal entre bandejas de 225 mm., estando las bandejas montadas dorso con dorso. Para distancias más pequeñas se reducirán los factores.</p>
<table border="1" cellpadding="2" width="360">
<tbody>
<tr>
<td colspan="2" rowspan="2" width="176" align="center">
<p align="center"><strong>Tipo de instalación</strong></p>
</td>
<td colspan="7" width="302" align="center"><strong>Nº de circuitos trifásicos (1)</strong></td>
</tr>
<tr>
<td width="95">
<p align="center"><strong>Nº de bandejas</strong></p>
</td>
<td width="40">
<p align="center"><strong>1</strong></p>
</td>
<td width="40">
<p align="center"><strong>2</strong></p>
</td>
<td width="40">
<p align="center"><strong>3</strong></p>
</td>
<td width="40">
<p align="center"><strong>4</strong></p>
</td>
<td width="41">
<p align="center"><strong>6</strong></p>
</td>
<td width="41">
<p align="center"><strong>9</strong></p>
</td>
</tr>
<tr>
<td rowspan="6" width="101" align="center">
<p align="center"><strong>Bandejas perforadas (2)</strong></p>
</td>
<td rowspan="3" width="144"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt7.gif"><img class="alignnone size-medium wp-image-1656" title="itc-bt7" src="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt7.gif" alt="" width="140" height="79" /></a></td>
<td width="95">
<p align="center">1</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">0,90</td>
<td width="40" align="center">0,80</td>
<td width="40" align="center">0,80</td>
<td width="41" align="center">0,75</td>
<td width="41" align="center">0,75</td>
</tr>
<tr>
<td width="95">
<p align="center">2</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">0,85</td>
<td width="40" align="center">0,80</td>
<td width="40" align="center">0.75</td>
<td width="41" align="center">0,75</td>
<td width="41" align="center">0.70</td>
</tr>
<tr>
<td width="95">
<p align="center">3</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">0,85</td>
<td width="40" align="center">0.80</td>
<td width="40" align="center">0,75</td>
<td width="41" align="center">0,70</td>
<td width="41" align="center">0,65</td>
</tr>
<tr>
<td rowspan="3" width="144"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt8.gif"><img class="alignnone size-medium wp-image-1657" title="itc-bt8" src="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt8.gif" alt="" width="135" height="80" /></a></td>
<td width="95">
<p align="center">1</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">0,95</td>
<td width="41" align="center">0,90</td>
<td width="41" align="center">-</td>
</tr>
<tr>
<td width="95">
<p align="center">2</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">0,95</td>
<td width="40" align="center">0,90</td>
<td width="41" align="center">0,85</td>
<td width="41" align="center">-</td>
</tr>
<tr>
<td width="95">
<p align="center">3</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">0,95</td>
<td width="40" align="center">0,90</td>
<td width="41" align="center">0,85</td>
<td width="41" align="center">-</td>
</tr>
<tr>
<td rowspan="4" width="101" align="center">
<p align="center"><strong>Bandejas verticales perforadas (3)</strong></p>
</td>
<td rowspan="2" width="144"><em><a href="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt9.gif"><img class="alignnone size-medium wp-image-1658" title="itc-bt9" src="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt9.gif" alt="" width="140" height="76" /></a></em></td>
<td width="95">
<p align="center">1</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">0,90</td>
<td width="40" align="center">0,80</td>
<td width="40" align="center">0,75</td>
<td width="41" align="center">0,75</td>
<td width="41" align="center">0,70</td>
</tr>
<tr>
<td width="95">
<p align="center">2</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">0,90</td>
<td width="40" align="center">0,80</td>
<td width="40" align="center">0,75</td>
<td width="41" align="center">0,70</td>
<td width="41" align="center">0,70</td>
</tr>
<tr>
<td rowspan="2" width="144"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt10.gif"><img class="alignnone size-medium wp-image-1661" title="itc-bt10" src="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt10.gif" alt="" width="141" height="94" /></a></td>
<td width="95">
<p align="center">1</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">0,90</td>
<td width="40" align="center">0,90</td>
<td width="40" align="center">0,90</td>
<td width="41" align="center">0,85</td>
<td width="41" align="center">-</td>
</tr>
<tr>
<td width="95">
<p align="center">2</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">0,90</td>
<td width="40" align="center">0,90</td>
<td width="40" align="center">0,85</td>
<td width="41" align="center">0,85</td>
<td width="41" align="center">-</td>
</tr>
<tr>
<td rowspan="6" width="101">
<p align="center"><strong>Bandejas escalera, soportes, etc, (2)</strong></p>
</td>
<td rowspan="3" width="144"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt11.gif"><img class="alignnone size-medium wp-image-1662" title="itc-bt11" src="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt11.gif" alt="" width="142" height="78" /></a></td>
<td width="95">
<p align="center">1</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">0,85</td>
<td width="40" align="center">0,80</td>
<td width="40" align="center">0,80</td>
<td width="41" align="center">0,80</td>
<td width="41" align="center">0,80</td>
</tr>
<tr>
<td width="95">
<p align="center">2</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">0,85</td>
<td width="40" align="center">0,80</td>
<td width="40" align="center">0,80</td>
<td width="41" align="center">0,75</td>
<td width="41" align="center">0,75</td>
</tr>
<tr>
<td width="95">
<p align="center">3</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">0,85</td>
<td width="40" align="center">0,80</td>
<td width="40" align="center">0,75</td>
<td width="41" align="center">0,75</td>
<td width="41" align="center">0,70</td>
</tr>
<tr>
<td rowspan="3" width="144"><a href="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt12.gif"><img class="alignnone size-medium wp-image-1663" title="itc-bt12" src="http://www.electricasas.com/wp-content/uploads/2008/11/itc-bt12.gif" alt="" width="142" height="84" /></a></td>
<td width="95">
<p align="center">1</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">1,00</td>
<td width="41" align="center">1,00</td>
<td width="41" align="center">-</td>
</tr>
<tr>
<td width="95">
<p align="center">2</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">0,95</td>
<td width="41" align="center">0,95</td>
<td width="41" align="center">-</td>
</tr>
<tr>
<td width="95">
<p align="center">3</p>
</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">1,00</td>
<td width="40" align="center">0,95</td>
<td width="40" align="center">0,95</td>
<td width="41" align="center">0,75</td>
<td width="41" align="center">-</td>
</tr>
</tbody>
</table>
<p>Tabla 15. Factor de corrección para agrupaciones de cables trifásicos</p>
<p>NOTAS:</p>
<p>(1) Incluye además el conductor neutro, si existiese.</p>
<p>(2) Los valores están indicados para una distancia vertical entre bandejas de 300 mm. Para distancias más pequeñas, se reducirán los factores.</p>
<p>(3) Los valores están indicados para una distancia horizontal entre bandejas de 225 mm., estando las bandejas montadas dorso con dorso. Para distancias más pequeñas se reducirán los factores.</p>
<p>1.2. Intensidades de cortocircuito admisibles en los conductores.</p>
<p>En las tablas 16 y 17 se indican las densidades de corriente de cortocircuito admisibles en los conductores de aluminio y de cobre de los cables aislados con diferentes materiales en función de los tiempos de duración del cortocircuito.</p>
<table border="1" cellspacing="1" cellpadding="4">
<tbody>
<tr>
<td rowspan="2" width="139" align="center" valign="top"><strong>Tipo de aislamiento</strong></td>
<td colspan="9" width="299" align="center" valign="top"><strong>Duración del cortocircuito, en segundos</strong></td>
</tr>
<tr>
<td width="26" align="center" valign="top">0.1</td>
<td width="24" align="center" valign="top">0.2</td>
<td width="26" align="center" valign="top">0.3</td>
<td width="26" align="center" valign="top">0.5</td>
<td width="21" align="center" valign="top">1.0</td>
<td width="21" align="center" valign="top">1.5</td>
<td width="21" align="center" valign="top">2.0</td>
<td width="21" align="center" valign="top">2.5</td>
<td width="21" align="center" valign="top">3.0</td>
</tr>
<tr>
<td width="139" align="center" valign="top">XLPE y EPR</td>
<td width="26" align="center" valign="top">294</td>
<td width="24" align="center" valign="top">203</td>
<td width="26" align="center" valign="top">170</td>
<td width="26" align="center" valign="top">132</td>
<td width="21" align="center" valign="top">93</td>
<td width="21" align="center" valign="top">76</td>
<td width="21" align="center" valign="top">66</td>
<td width="21" align="center" valign="top">59</td>
<td width="21" align="center" valign="top">54</td>
</tr>
<tr>
<td width="139" align="center" valign="bottom">
<p align="center">PVC</p>
<p align="center">Sección <strong>≤ </strong>300 mm<sup>2</sup></p>
<p align="center">Sección &gt; 300 mm<sup>2</sup></p>
</td>
<td width="26" align="center" valign="bottom">237211</td>
<td width="24" align="center" valign="bottom">168150</td>
<td width="26" align="center" valign="bottom">137122</td>
<td width="26" align="center" valign="bottom">10694</td>
<td width="21" align="center" valign="bottom">7567</td>
<td width="21" align="center" valign="bottom">6154</td>
<td width="21" align="center" valign="bottom">5347</td>
<td width="21" align="center" valign="bottom">4742</td>
<td width="21" align="center" valign="bottom">4339</td>
</tr>
</tbody>
</table>
<p>Tabla 16. Densidad de corriente de cortocircuito, en A/mm2, para conductores de aluminio.</p>
<table border="1" cellspacing="1" cellpadding="4" width="366">
<tbody>
<tr>
<td rowspan="2" width="168" align="center" valign="top">
<div><strong>Tipo de aislamiento</strong></div>
</td>
<td colspan="9" width="341" align="center" valign="top">
<div><strong>Duración del cortocircuito, en segundos</strong></div>
</td>
</tr>
<tr>
<td width="35" align="center" valign="top">
<div>0.1</div>
</td>
<td width="26" align="center" valign="top">
<div>0.2</div>
</td>
<td width="26" align="center" valign="top">
<div>0.3</div>
</td>
<td width="26" align="center" valign="top">
<div>0.5</div>
</td>
<td width="26" align="center" valign="top">
<div>1.0</div>
</td>
<td width="26" align="center" valign="top">
<div>1.5</div>
</td>
<td width="26" align="center" valign="top">
<div>2.0</div>
</td>
<td width="23" align="center" valign="top">
<div>2.5</div>
</td>
<td width="31" align="center" valign="top">
<div>3.0</div>
</td>
</tr>
<tr>
<td width="168" align="center" valign="top">
<div>XLPE y EPR</div>
</td>
<td width="35" align="center" valign="top">
<div>449</div>
</td>
<td width="26" align="center" valign="top">
<div>318</div>
</td>
<td width="26" align="center" valign="top">
<div>259</div>
</td>
<td width="26" align="center" valign="top">
<div>201</div>
</td>
<td width="26" align="center" valign="top">
<div>142</div>
</td>
<td width="26" align="center" valign="top">
<div>116</div>
</td>
<td width="26" align="center" valign="top">
<div>100</div>
</td>
<td width="23" align="center" valign="top">
<div>90</div>
</td>
<td width="31" align="center" valign="top">
<div>82</div>
</td>
</tr>
<tr>
<td width="168" align="center" valign="bottom">
<div>PVC</div>
<p align="left">Sección <strong>≤ </strong>300 mm<sup>2</sup></p>
<p align="left">Sección &gt; 300 mm<sup>2</sup></p>
</td>
<td width="35" align="center" valign="bottom">
<div>364</div>
<p align="left">322</p>
</td>
<td width="26" align="center" valign="bottom">
<div>257</div>
<p align="left">228</p>
</td>
<td width="26" align="center" valign="bottom">
<div>210</div>
<p align="left">186</p>
</td>
<td width="26" align="center" valign="bottom">
<div>163</div>
<p align="left">144</p>
</td>
<td width="26" align="center" valign="bottom">
<div>115</div>
<p align="left">102</p>
</td>
<td width="26" align="center" valign="bottom">
<div>94</div>
<p align="left">83</p>
</td>
<td width="26" align="center" valign="bottom">
<div>81</div>
<p align="left">72</p>
</td>
<td width="23" align="center" valign="bottom">
<div>73</div>
<p align="left">64</p>
</td>
<td width="31" align="center" valign="bottom">
<div>66</div>
<p align="left">59</p>
</td>
</tr>
</tbody>
</table>
<p>Tabla 17 Densidad de corriente de cortocircuito, en A/mm2, para conductores de cobre.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/intensidad-maxima-admisible-en-cables-subterraneos/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Los cables eléctricos podrían clasificarse:</title>
		<link>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/cables-conductores-electricos-clasificacion-tipos-de-cables-electricos/</link>
		<comments>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/cables-conductores-electricos-clasificacion-tipos-de-cables-electricos/#comments</comments>
		<pubDate>Tue, 07 Oct 2008 16:33:59 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Conductores]]></category>
		<category><![CDATA[ahorrar electricidad]]></category>
		<category><![CDATA[cable electrico]]></category>
		<category><![CDATA[cables conductores electricos]]></category>
		<category><![CDATA[circuitos electricos]]></category>
		<category><![CDATA[colores cables electricos]]></category>
		<category><![CDATA[conductores electricos]]></category>
		<category><![CDATA[corriente electrica]]></category>
		<category><![CDATA[electricidad estatica]]></category>
		<category><![CDATA[instalaciones electricas]]></category>
		<category><![CDATA[la electricidad]]></category>
		<category><![CDATA[la instalacion electrica de una vivienda]]></category>
		<category><![CDATA[magnetismo y electricidad]]></category>
		<category><![CDATA[manual de electricidad]]></category>
		<category><![CDATA[materiales electricos]]></category>
		<category><![CDATA[simbolos electricos]]></category>
		<category><![CDATA[sitio de electricidad]]></category>
		<category><![CDATA[tipos de cables]]></category>
		<category><![CDATA[tipos de cables electricos]]></category>
		<category><![CDATA[tipos de conectores]]></category>

		<guid isPermaLink="false">http://www.electricasas.com/?p=1111</guid>
		<description><![CDATA[1. Por su función:
(a) Cables para el transporte de energía
(b) Cables de control y para transmisión de señales codificadas
2. Por su tensión de servicio:
(a) De muy baja tensión (menos de 50 V.)
(b) Baja tensión (más de 50 V y hasta 1,1 kV.)
(c) Media tensión (más de 1,1 kV hasta 35 kV.)
(d) Alta tensión (más de [...]]]></description>
			<content:encoded><![CDATA[<p>1. Por su función:<br />
(a) Cables para el transporte de energía<br />
(b) Cables de control y para transmisión de señales codificadas</p>
<p>2. Por su tensión de servicio:<br />
(a) De muy baja tensión (menos de 50 V.)<br />
(b) Baja tensión (más de 50 V y hasta 1,1 kV.)<br />
(c) Media tensión (más de 1,1 kV hasta 35 kV.)<br />
(d) Alta tensión (más de 35 kV hasta 150 kV.)<br />
(e) Muy alta tensión (por encima de 150 kV.)</p>
<p>3. Por la naturaleza de sus componentes:<br />
(a) Con conductores de cobre o aluminio<br />
(b) Aislados con plástico, goma o papel impregnado<br />
(c) Armados, apantallados, etc</p>
<p>4. Por sus aplicaciones específicas:<br />
(a) Para instalaciones interiores en edificios<br />
(b) Para redes de distribución de energía, urbanas o rurales<br />
(c) De señalización, telefonía, radiofrecuencia, etc<br />
(d) Para minas, construcción naval, ferrocarriles, etc</p>
<p><span id="more-1111"></span></p>
<p>Son los elementos metálicos, generalmente cobre o aluminio, permeables al paso de la corriente eléctrica y que, por lo tanto, cumplen la función de transportar la “presión electrónica” de un extremo al otro del cable. Los metales mencionados se han elegido por su alta conductividad, característica necesaria para optimizar la transmisión de energía.</p>
<p>Los alambres y cuerdas se conforman a partir de estas materias primas y se construyen de acuerdo con las respectivas normas nacionales e internacionales, tales como las Normas IRAM 2176, 2177, 2022, 2204 y la norma de la Comisión Electrotécnica Internacional IEC 228.</p>
<p>Además de su naturaleza material, los cables deben ser capaces de ajustarse a las características de la instalación donde van destinados. Es ocasiones el recorrido de la línea es más o menos sinuoso, o inclusive puede ser necesario que acompañe al equipo que alimenta en su desplazamiento durante el servicio.</p>
<p>Por esta razón, los conductores de la misma sección pueden estar constituidos por haces de hilos metálicos de distinto diámetro, según la mayor o menor flexibilidad exigida al cable.<br />
La mayoría de las normas clasifica a los conductores desde el más rígido (clase 1), constituido por un solo alambre, al más flexible (clase 6), formado por haces de hilos extremadamente finos.</p>
<p>Para las secciones iguales o superiores a 10mmª suele utilizarse cuerdas compactas que permiten obtener cables de inferiores dimensiones.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/cables-conductores-electricos-clasificacion-tipos-de-cables-electricos/feed/</wfw:commentRss>
		<slash:comments>3</slash:comments>
		</item>
		<item>
		<title>Asi se construyen los conductores.</title>
		<link>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/asi-se-construyen-los-conductores/</link>
		<comments>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/asi-se-construyen-los-conductores/#comments</comments>
		<pubDate>Mon, 29 Sep 2008 03:08:59 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Conductores]]></category>
		<category><![CDATA[aluminio]]></category>
		<category><![CDATA[casas]]></category>
		<category><![CDATA[cobre]]></category>
		<category><![CDATA[construccion]]></category>
		<category><![CDATA[electricasas]]></category>
		<category><![CDATA[Electricidad]]></category>
		<category><![CDATA[fabricacion]]></category>
		<category><![CDATA[hogar]]></category>
		<category><![CDATA[video]]></category>

		<guid isPermaLink="false">http://www.electricasas.com/?p=1013</guid>
		<description><![CDATA[El siguiente video muestra la fabricación de cables electricos.

]]></description>
			<content:encoded><![CDATA[<p>El siguiente video muestra la fabricación de cables electricos.</p>
<div style="text-align: center;"><object classid="clsid:d27cdb6e-ae6d-11cf-96b8-444553540000" width="425" height="349" codebase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=6,0,40,0"><param name="allowFullScreen" value="true" /><param name="src" value="http://www.youtube.com/v/CcOH5P_gF_I&amp;hl=en&amp;fs=1&amp;rel=0&amp;color1=0x2b405b&amp;color2=0x6b8ab6&amp;border=1" /><embed type="application/x-shockwave-flash" width="425" height="349" src="http://www.youtube.com/v/CcOH5P_gF_I&amp;hl=en&amp;fs=1&amp;rel=0&amp;color1=0x2b405b&amp;color2=0x6b8ab6&amp;border=1" allowfullscreen="true"></embed></object></div>
]]></content:encoded>
			<wfw:commentRss>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/asi-se-construyen-los-conductores/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Instalaciones con conductores aislados en cañerías</title>
		<link>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/instalaciones-con-conductores-aislados-en-canerias/</link>
		<comments>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/instalaciones-con-conductores-aislados-en-canerias/#comments</comments>
		<pubDate>Mon, 01 Sep 2008 19:15:46 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Conductores]]></category>
		<category><![CDATA[a la vista]]></category>
		<category><![CDATA[Aislacion]]></category>
		<category><![CDATA[Aislaciones]]></category>
		<category><![CDATA[alumbrado]]></category>
		<category><![CDATA[cables]]></category>
		<category><![CDATA[Cajas]]></category>
		<category><![CDATA[Cañerias]]></category>
		<category><![CDATA[caños]]></category>
		<category><![CDATA[casa]]></category>
		<category><![CDATA[cielorraso]]></category>
		<category><![CDATA[Circuitos]]></category>
		<category><![CDATA[codigo colores]]></category>
		<category><![CDATA[corriente]]></category>
		<category><![CDATA[curvado]]></category>
		<category><![CDATA[derivaciones]]></category>
		<category><![CDATA[Electricidad]]></category>
		<category><![CDATA[electrico]]></category>
		<category><![CDATA[Embutidas]]></category>
		<category><![CDATA[empalmes]]></category>
		<category><![CDATA[fase]]></category>
		<category><![CDATA[Fuerza Motriz]]></category>
		<category><![CDATA[hogar]]></category>
		<category><![CDATA[instalacion]]></category>
		<category><![CDATA[iram]]></category>
		<category><![CDATA[lineas]]></category>
		<category><![CDATA[Materiales]]></category>
		<category><![CDATA[montante]]></category>
		<category><![CDATA[neutro]]></category>
		<category><![CDATA[potencia]]></category>
		<category><![CDATA[rablero]]></category>
		<category><![CDATA[secciones]]></category>
		<category><![CDATA[tendido]]></category>
		<category><![CDATA[tension]]></category>
		<category><![CDATA[tomacorrientes]]></category>
		<category><![CDATA[vivo]]></category>

		<guid isPermaLink="false">http://electricasa.com.ar.elserver.com/?p=648</guid>
		<description><![CDATA[-Agrupar conductores en un mismo caño.

Deben cumplir los siguientes requisitos:
a) Todos los conductores de una misma línea (vivo y neutro) en monofásica o tres fases y neutro (trifásica), cuando están protegidos en un caño metálico, deben estarlo en conjunto, no individualmente. Si no fuera así el campo magnético resultante generaría calentamiento y pérdidas (efecto skin) [...]]]></description>
			<content:encoded><![CDATA[<p><span style="font-size: x-small;"><span style="font-family: Verdana;"><strong>-Agrupar conductores en un mismo caño.<br />
</strong></span></span></p>
<p><span style="font-size: x-small;"><span style="font-family: Verdana;">Deben cumplir los siguientes requisitos:</span></span></p>
<p><span style="font-size: x-small; font-family: Verdana;">a) Todos los conductores de una misma línea (vivo y neutro) en monofásica o tres fases y neutro (trifásica), cuando están protegidos en un caño metálico, deben estarlo en conjunto, no individualmente. Si no fuera así el campo magnético resultante generaría calentamiento y pérdidas (efecto skin) en el caño de hierro. Debe incluirse el conductor de protección. </span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;">b) Las líneas de circuitos seccionales que provienen del tablero respectivo deben alojarse en caños independientes. Sin embargo se admiten más de una línea seccional (tres como máximo, si provienen del mismo medidor -fase-).</span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;">c) Las líneas de alumbrado y de tomacorrientes (usos generales, de la misma fase, pueden alojarse en una misma cañería). Las líneas de circuito de conexión fija o de circuitos especiales, deben tener cañerías independientes para cada una de ellas. Cuando decimos circuitos de conexión fija nos referimos a la alimentación de motores, bombeadores, etc., que no usan tomacorrientes, pueden ser mono o trifásicas.<br />
Cuando decimos circuitos especiales, hacemos referencia a aquellos que alimentan cargas de más de 10A a través de tomacorrientes o a la alimentación de jardines, parques, etc. Estos circuitos especiales tendrán una limitación en su potencia de alimentación ya que sus protecciones no superarán los 25A. </span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;">d) En un mismo caño se pueden alojar como máximo:<br />
- Tres líneas de circuitos (uso general) de la misma fase.<br />
- Carga máxima simultánea 20A.<br />
- Número total de bocas que alimentan estos circuitos. No debe ser superior a 15 unidades.</span></p>
<p><span id="more-648"></span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>Nota: </strong><br />
Como el reglamento admite el uso de caños de plástico para cañerías embutidas, Norma IRAM 2206, estas limitaciones de potencia eléctrica de carga, es importante que sea respetado, por las máximas temperaturas que se permiten pueda llegar en la aislación de un conductor (PVC de mayor uso) que son de 160°C en no más de 5 seg. </span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><br />
<strong>Tabla I<br />
Temperaturas máximas en el conductor</strong></span></p>
<div> </div>
<table border="1" cellspacing="0" cellpadding="0" width="80%" align="center">
<tbody>
<tr bgcolor="#999999">
<td width="40%"><span style="font-size: xx-small; color: #ffffff; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>Compuesto<br />
aislante </strong></span></td>
<td width="20%"><span style="font-size: xx-small; color: #ffffff; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>Operación<br />
normal ºC</strong></span></td>
<td width="20%"><span style="font-size: xx-small; color: #ffffff; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>Cortocircuito<br />
(duración máxima 5 seg)ºC</strong></span></td>
<td width="20%"><span style="font-size: xx-small; color: #ffffff; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>Sobrecarga de emergencia<br />
ºC </strong><sub>(1)</sub></span></td>
</tr>
<tr>
<td width="40%" height="22"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">1) Policloruro de vinilo (PVC)</span></td>
<td width="20%"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">70</span></td>
<td width="20%"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">160</span></td>
<td width="20%"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">-</span></td>
</tr>
<tr>
<td width="40%" height="22"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">2) Polietileno reticulado (XLPE)</span></td>
<td width="20%"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">90</span></td>
<td width="20%"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">250</span></td>
<td width="20%"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">130</span></td>
</tr>
<tr>
<td width="40%" height="22"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">3) Caucho de etileno propileno (EPR)</span></td>
<td width="20%"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">90</span></td>
<td width="20%"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">250</span></td>
<td width="20%"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">130</span></td>
</tr>
</tbody>
</table>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;">(1) Durante emergencias la operación de sobrecarga no debe sobrepasar 100 horas (durante 12 meses seguidos, ni superar 500 horas durante la vida del cable).</span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;">e) En todas las cajas donde converjan líneas de diferentes circuitos, los conductores deberán estar identificados por colores (ver 7.2.5.), anillos numerados, cintas autoadhesivas, etc.; de manera de evitar que, por error, puedan interconectarse conductores vivos entre sí o neutros entre sí, de diferentes circuitos. </span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;">f) En una misma boca de salida no podrán instalarse elementos (interruptores de efecto o tomacorrientes), alimentados por diferentes circuitos.</span></p>
<p align="center"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>Métodos de instalación de cables y conductores.<br />
Montaje en relación a influencias externas </strong></span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>1) Temperatura ambiente </strong></span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;">Deberán seleccionarse y montarse apropiadamente en relación a la mínima y máxima temperatura ambiente encontrada y con la corrección de sobrecarga que esas temperaturas determinen. </span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>2) Fuentes de calor (solar, etc.) </strong><br />
Para evitar sus efectos sobre los cables deberán protegerse a estos por los métodos siguientes: </span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;">a) Acorazarlos con envolturas apropiadas.<br />
b) Montarlos suficientemente lejos de la fuente de calor.<br />
c) Seleccionar su aislación térmica en relación al aumento de la temperatura que pueda ocurrir.<br />
d) Reducir la capacidad de corriente. </span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>Nota:</strong><br />
Los cables dentro de accesorios, aparatos o luminarias, deberán ser apropiados a la temperatura del habitáculo donde se encuentren. Ejemplos: plafones de iluminación de interior incandescentes fluorescentes o exterior (mercurio, sodio, etc.). Se los reforzará con materiales aislantes especiales (spaguettis de vidrio epoxi o caucho silicona, etc.). </span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>3) Presencia de agua o humedad </strong></span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;">a) Se seleccionará de forma que ningún daño se cause a los cables por ingreso de agua o humedad durante la instalación, uso y mantenimiento.<br />
b) Donde el agua pueda ocluirse, por condensación u otra causa deberán proveerse puntos de drenaje. </span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>4) Presencia de cuerpos sólidos extraños, polvos, etc. </strong></span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;">a) Se seleccionará y montará de manera de minimizar el ingreso de cuerpos sólidos (polvo, etc.) durante la instalación, uso y mantenimiento, de forma de no afectar la disipación del calor de los conductores. </span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>7.2.2- Diámetro mínimo de los caños</strong><br />
El diámetro interno mínimo de los caños se determinará en función de la cantidad, sección y diámetro (incluída la aislación) de los conductores. Para los casos no previstos en la tabla, el área total ocupada por los conductores, comprendida la aislación, no deberá exceder el 35% de la sección interna del caño.<br />
<em>El diámetro interno mínimo de los caños que alojen líneas seccionales y principales deberá ser de 15,3mm. El diámetro interno mínimo de los caños que alojen líneas de circuito deberá ser de 12,5mm. </em></span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>7.2.3- Colocación de caños y cajas </strong></span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>7.2.3.1- Unión entre caños </strong><br />
Los caños se unirán entre sí mediante accesorios adecuados que no disminuyan su sección interna y que aseguren la protección mecánica de los conductores.<br />
<em>Cuando se empleen caños metálicos deberá garantizarse la continuidad eléctrica de la cañería.</em><br />
Se ejecutarán mediante accesorios que no disminuyan su sección interna de modo de no originar dificultades en el pasaje de los conductores y con ello su deterioro o corte de la malla de aislación. El elemento que cumple con la condición ideal de unión es la “cupla roscada”, no admitiéndose el uso de trozos de caños de mayor sección, pues no se garantiza evitar el marcado de la aislación de los conductores en el pasaje de los mismos. </span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>7.2.3- Unión entre caño y caja</strong><br />
Las uniones de caños y cajas deberán efectuarse mediante conectores o tuerca y boquilla. La tuerca se dispondrá en la parte exterior de la caja y la boquilla en su parte interna. Las características constructivas de estos elementos estarán en concordancia con las prescriptas por las normas IRAM 2224 y 2005. </span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>7.2.3.3- Colocación de cajas de paso </strong>Para facilitar la colocación y el remplazo de conductores de conductores deberá emplearse un número suficiente de cajas de paso. No se admitirán más de tres curvas entre dos cajas. En tramos rectos y horizontales sin derivación debe colocarse una caja cada 12m y en tramos verticales una cada 15m. Las cajas de paso y de derivación deberán instalarse de tal modo que sean siempre accesibles y que no sean tapados por amoblamiento previsto como fijo (muebles de cocina, etc.). </span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>7.2.3.4- Consideraciones para caños en forma de “U” </strong><br />
Cuando no sea posible evitar la colocación de caños en forma de “U” (por ejemplo, los cruces bajo los pisos) u otra forma que facilite la acumulación de agua se colocarán únicamente cables aislados con vaina de protección (llamadas comúnmente de doble aislación) que respondan a las normas IRAM 2220, 2262 y 2261. </span></p>
<p><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>7.2.3.5- Curvado de los caños</strong><br />
Las curvas realizadas en los caños no deberán efectuarse con ángulos menores de 90. Además deberán tener como mínimo los radios de curvatura indicados en la siguiente tabla. </span><br />
<span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong></strong></span></p>
<p style="text-align: center;"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>Tabla II</strong></span></p>
<table border="1" cellspacing="0" cellpadding="0" width="80%" align="center">
<tbody>
<tr bgcolor="#999999">
<td width="33%" height="50"><span style="font-size: xx-small; color: #ffffff; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>Caño tipo liviano<br />
Designación<br />
IRAM </strong></span></td>
<td width="33%"><span style="font-size: xx-small; color: #ffffff; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>Caño tipo<br />
Semipesado<br />
Designación IRAM</strong></span></td>
<td width="33%"><span style="font-size: xx-small; color: #ffffff; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>Radio de<br />
curvatura<br />
mínimo (mm)</strong></span></td>
</tr>
<tr>
<td width="33%" height="100"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">RL 16/14<br />
RL 19/17<br />
RL 22/20<br />
RL 25/23<br />
RL 32/29<br />
RL 38/35<br />
RL 51/48</span></td>
<td width="33%"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">RS 16/13<br />
RS 19/15<br />
RS 22/18<br />
RS 25/21<br />
RS 32/28<br />
RS 38/34<br />
RS 51/46</span></td>
<td width="33%"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">47,5<br />
56<br />
67<br />
75<br />
95<br />
112<br />
150</span></td>
</tr>
</tbody>
</table>
<p align="left"><strong></strong></p>
<p><strong>7.2.4- Colocación de los conductores<br />
</strong>Antes de instalar los conductores deberán haberse concluído el montaje de caños y cajas y completado los trabajos de mampostería y terminaciones superficiales. Deberá dejarse una longitud mínima de 15cm de conductor disponible en cada caja a los efectos de poder realizar las conexiones necesarias. Los conductores que pasen sin empalme a través de las cajas deberán formar un bucle. Los conductores colocados en cañerías verticales deberán estar soportados a distancias no mayores de 15m mediante piezas colocadas en cajas accesibles y con formas y disposiciones tales que no dañen su cubierta aislante.<br />
No se permiten uniones ni derivaciones de conductores en el interior de los caños, las cuales deberán efectuarse exclusivamente en las cajas. </p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>7.2.5. Código de colores</strong><br />
Los conductores de la Norma IRAM 2183 y barras conductoras se identificarán con los siguientes colores: </span></p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;">Neutro: color celeste<br />
Conductor de protección: bicolor verde-amarillo<br />
Fase R: color castaño<br />
Fase S: color negro<br />
Fase T: color rojo<br />
Para los conductores de las fases se admitirán otros colores, excepto el verde, amarillo o celeste.<br />
Para el conductor de fase de las instalaciones monofásicas se podrá utilizar indistintamente cualquiera de los colores indicados para las fases pero se preferirá el castaño. </span></p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>7.2.6- Secciones mínimas de los conductores </strong><br />
Se respetarán las siguientes secciones mínimas </span></p>
<table border="1" cellspacing="0" cellpadding="0" width="90%" align="center">
<tbody>
<tr>
<td>
<table border="0" width="100%">
<tbody>
<tr>
<td height="23"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">Líneas principales</span></td>
<td height="23"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">4mm<sup>2</sup></span></td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td>
<table border="0" width="100%">
<tbody>
<tr>
<td height="23"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">Líneas seccionales</span></td>
<td height="23"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">2,5mm<sup>2</sup></span></td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td>
<table border="0" width="100%">
<tbody>
<tr>
<td height="23"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">Líneas de circuitos para usos generales</span></td>
<td height="23"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">1,5,mm<sup>2</sup></span></td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td>
<table border="0" width="100%">
<tbody>
<tr>
<td height="23"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">Líneas de circuitos para usos especiales y/o conexión fija</span></td>
<td height="23"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">2,5mm<sup>2</sup></span></td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td>
<table border="0" width="100%">
<tbody>
<tr>
<td height="23"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">Derivaciones y retorno a los interruptores de efecto</span></td>
<td height="23"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">1mm<sup>2</sup></span></td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td>
<table border="0" width="100%">
<tbody>
<tr>
<td height="23"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">Conductor de protección</span></td>
<td height="23"><span style="font-size: xx-small; font-family: Verdana, Arial, Helvetica, sans-serif;">2,5mm<sup>2</sup></span></td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
<p align="center"> </p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>7.2.7- Prescripciones particulares para cañerías embutidas</strong> </span></p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>7.2.7.1-</strong> Las cañerías y los accesorios para instalaciones embutidas en techos, pisos y paredes deberán ser de acero tipo pesado, semipesado o liviano y cumplir con las prescripciones dadas en las Normas IRAM 2100, 2005 y 2224 respectivamente. </span></p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>2.7.7.2-</strong> En caño termoplástico Norma IRAM 2206 se admitirá embutido en las siguientes condiciones: </span></p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;">a) La distancia entre la superficie terminada de la pared y el caño no será inferior a 5cm. </span></p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;">b) Quedan exceptuadas de cumplir el punto a) las cañerías ubicadas en una franja comprendida entre 10 y 15cm., tomada a partir de las aberturas de puertas y ventanas, medidas en la construcción de albañilería sin terminar y además en el entorno de las cajas.<br />
Se admitirán solo las de tipo de caño reforzado y <strong>colocadas de modo de no entrar en contacto con los revoques de tipo calcáreo de paredes.</strong> Para ese fin se colocará la cañería en un canal que se efectuará en ladrillos, bloques, etc., tapándola totalmente con mezcla de cemento de modo que el revoque posterior no entre en contacto con la cañería y se brinde una mínima seguridad a la penetración posterior de clavos. La cañería no debe quedar suelta ni establecerse por orificios de ladrillos o bloques de la construcción. En losas se asegurarán con dispositivos adecuados para evitar su aplastamiento o que queden sueltas entre los hierros de la construcción.<br />
<strong>Es aceptado el caño que no sea autoextingüible en este caso.</strong> </span></p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>7.2.8- Prescripciones particulares para cañerías a la vista y/o sobre cielorrasos suspendidos </strong></span></p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>7.2.8.1- Cañerías a la vista</strong><br />
Podrán emplearse: las cañerías metálicas que se utilizan embutidas. </span></p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;">Además podrán emplearse:<br />
a) Cañería de acero tipo liviano, según Norma IRAM 2284, esmaltadas o cincadas con uniones y accesorios normalizados.<br />
b) Cañerías formadas por conductores metálicos fabricados especialmente para instalaciones eléctricas a la vista, utilizando accesorios tales como cajas, codos, etc., fabricados especialmente para éstos.<br />
c) Caños metálicos flexibles.<br />
<strong>d) <em>Caños de material termoplástico</em>, siempre que tengan un grado de protección mecánica equivalente al IPXX1 de la Norma IRAM 2444, y resistan al ensayo de propagación de llama establecida en la Norma IEC 695-2-1, con un grado de severidad de 550°C, además de las características dieléctricas adecuadas. </strong></span></p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>Notas: </strong><br />
Los tipos indicados en este apartado deberán emplearse en lugares secos para locales con condiciones especiales. </span></p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>Las cañerías a la vista no deberán instalarse en huecos de ascensores ni en lugares donde queden expuestas a deterioros mecánicos o químicos. </strong></span></p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>7.2.8.2- Cañerías sobre cielorrasos suspendidos</strong><br />
Podrán utilizarse todos los tipos de caños indicados para instalaciones a la vista, a excepción de los caños flexibles metálicos. </span></p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>7.2.9- Prescripciones particulares para columnas montantes</strong><br />
Los requisitos que deberán cumplir las líneas seccionales en las cajas de paso y derivación de la columna montante serán: </span></p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;">• Identificación mediante letras, números o combinación de ambos.<br />
• Evitar el entrecruzamiento de los conductores de las distintas líneas. </span></p>
<p align="left"><span style="font-size: x-small; font-family: Verdana, Arial, Helvetica, sans-serif;"><strong>Nota El único conductor aceptado es el que resiste el ensayo de propagación de llama establecido en la Norma IRAM 2183 de 1991</strong></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/instalaciones-con-conductores-aislados-en-canerias/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Conductores: IRAM 2342, 2158 y 2179</title>
		<link>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/conductores-iram-2342-2158-y-2179/</link>
		<comments>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/conductores-iram-2342-2158-y-2179/#comments</comments>
		<pubDate>Sat, 30 Aug 2008 02:55:21 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Conductores]]></category>
		<category><![CDATA[Aislacion]]></category>
		<category><![CDATA[bajada]]></category>
		<category><![CDATA[cables]]></category>
		<category><![CDATA[casa]]></category>
		<category><![CDATA[Circuitos]]></category>
		<category><![CDATA[cobre]]></category>
		<category><![CDATA[conexion]]></category>
		<category><![CDATA[Continuidad]]></category>
		<category><![CDATA[corriente]]></category>
		<category><![CDATA[derivaciones]]></category>
		<category><![CDATA[descargas]]></category>
		<category><![CDATA[Electricidad]]></category>
		<category><![CDATA[electrico]]></category>
		<category><![CDATA[empalmes]]></category>
		<category><![CDATA[esctructuras]]></category>
		<category><![CDATA[fase]]></category>
		<category><![CDATA[hogar]]></category>
		<category><![CDATA[inmuebles]]></category>
		<category><![CDATA[instalacion]]></category>
		<category><![CDATA[Interruptores]]></category>
		<category><![CDATA[iram]]></category>
		<category><![CDATA[lineas]]></category>
		<category><![CDATA[masas]]></category>
		<category><![CDATA[neutro]]></category>
		<category><![CDATA[Protecciones]]></category>
		<category><![CDATA[resistencia]]></category>
		<category><![CDATA[sistemas]]></category>
		<category><![CDATA[tendido]]></category>
		<category><![CDATA[tension]]></category>
		<category><![CDATA[vivo]]></category>

		<guid isPermaLink="false">http://electricasa.com.ar.elserver.com/?p=567</guid>
		<description><![CDATA[Características que definen la calidad 
I) Espesor aislante 
Valores
Tipo 1
Espesor individual de la tabla Tipo 1 (ver más abajo) para espesores promedios.
Espesor envoltura: El espesor mínimo será &#62;= 0,90 espesor normal -0,1 en mm. 






















II) Ensayos eléctricos:
a) En cables completos: Se sumerge en agua, una longitud de 10m, durante una hora a una temperatura de [...]]]></description>
			<content:encoded><![CDATA[<p><span style="font-size: x-small; font-family: Verdana,Arial,Helvetica,sans-serif;"><strong><em>Características que definen la calidad </em></strong></span></p>
<p><span style="font-size: x-small; font-family: Verdana,Arial,Helvetica,sans-serif;"><strong>I) Espesor aislante </strong><br />
<strong>Valores</strong><br />
Tipo 1<br />
<strong>Espesor individual</strong> de la tabla Tipo 1 (ver más abajo) para espesores promedios.<br />
<strong>Espesor envoltura:</strong> El espesor mínimo será &gt;= 0,90 espesor normal -0,1 en mm. </span></p>
<table border="0" align="center">
<tbody>
<tr>
<td>
<div style="text-align: center;"><span style="font-size: x-small; font-family: Verdana,Arial,Helvetica,sans-serif;"><a href="http://electricasa.com.ar.elserver.com/wp-content/uploads/2008/08/fig11.jpg"><img class="alignnone size-medium wp-image-568" title="fig11" src="http://electricasa.com.ar.elserver.com/wp-content/uploads/2008/08/fig11.jpg" alt="" /></a></span></td>
</tr>
<tr>
<td>
<div style="text-align: center;"><span style="font-size: x-small; font-family: Verdana,Arial,Helvetica,sans-serif;"><a href="http://electricasa.com.ar.elserver.com/wp-content/uploads/2008/08/fig21.jpg"><img class="alignnone size-medium wp-image-569" title="fig21" src="http://electricasa.com.ar.elserver.com/wp-content/uploads/2008/08/fig21.jpg" alt="" /></a></span></td>
</tr>
<tr>
<td>
<div style="text-align: center;"><span style="font-size: x-small; font-family: Verdana,Arial,Helvetica,sans-serif;"><a href="http://electricasa.com.ar.elserver.com/wp-content/uploads/2008/08/fig31.jpg"><img class="alignnone size-medium wp-image-570" title="fig31" src="http://electricasa.com.ar.elserver.com/wp-content/uploads/2008/08/fig31.jpg" alt="" /></a></span></td>
</tr>
<tr>
<td>
<div style="text-align: center;"><span style="font-size: x-small; font-family: Verdana,Arial,Helvetica,sans-serif;"><a href="http://electricasa.com.ar.elserver.com/wp-content/uploads/2008/08/fig41.jpg"><img class="alignnone size-medium wp-image-571" title="fig41" src="http://electricasa.com.ar.elserver.com/wp-content/uploads/2008/08/fig41.jpg" alt="" /></a></span></td>
</tr>
</tbody>
</table>
<p align="left">
<p><span id="more-567"></span><br />
<span style="font-size: x-small; font-family: Verdana,Arial,Helvetica,sans-serif;"><strong>II) Ensayos eléctricos:</strong></span><br />
<span style="font-size: x-small; font-family: Verdana,Arial,Helvetica,sans-serif;"><strong>a) En cables completos:</strong> Se sumerge en agua, una longitud de 10m, durante una hora a una temperatura de 20 ±5°C. Se aplica la tensión de 2000VCA (hasta Un = 500V), entre cada conductor y todos los otros conectados entre sí y con el agua durante 5 minutos. No debe haber ninguna falla. </span></p>
<p><span style="font-size: x-small; font-family: Verdana,Arial,Helvetica,sans-serif;"><strong>b) En los conductores aislados individuales:</strong> Cada uno individualmente se sumerge en agua con un largo de 10 metros, durante una hora a una temperatura de 20 ± 5°C. Se aplica una tensión de CA de 1500V hasta espesores de 0,6mm y de 2000V para mayor de espesores de 0,6 durante 5 minutos entre cada conductor y el agua. No debe haber ninguna falla.</span></p>
<p><span style="font-size: x-small; font-family: Verdana,Arial,Helvetica,sans-serif;"><strong>III) Resistencia de aislación:</strong> Se aplica a todos los cables sobre muestras de 10m de largo sumergidos en agua a 70 °C durante dos horas. Se aplica una tensión continua entre 300 y 500 V entre el conductor y el agua. Se mide la resistencia de aislación un minuto después de aplicada dicha tensión y se relaciona con 1 km (supuestamente) 100 veces menos. </span><br />
<span style="font-size: x-small; font-family: Verdana,Arial,Helvetica,sans-serif;"><strong>IV) Ensayo de resistencia mecánica de cables completos </strong><br />
<strong>Ensayo de flexión:</strong> Para conductores hasta 2,5mm2. En el aparato indicado en la figura 1 . 15.000 movimientos hacia adelante y 15.000 hacia atrás, con un pasaje de corriente de 1 A/m2 y 220VCA aplicados para cables bipolares o contra conductor de protección y 330VCA para tres conductores o tres con neutro.</span></p>
<table border="1" cellspacing="0" cellpadding="0" width="90%" align="center">
<tbody>
<tr bgcolor="#ccffff">
<td rowspan="2" width="10%" bgcolor="#999999">
<span style="font-size: xx-small; color: #ffffff; font-family: Verdana,Arial,Helvetica,sans-serif;"><strong>Sección<br />
(mm<sup>2</sup>) </strong></span></td>
<td rowspan="2" width="10%" bgcolor="#999999">
<span style="font-size: xx-small; color: #ffffff; font-family: Verdana,Arial,Helvetica,sans-serif;"><strong>Aislación<br />
espesor<br />
promedio<br />
(mm) </strong></span></td>
<td colspan="4" width="30%" bgcolor="#999999">
<span style="font-size: xx-small; color: #ffffff; font-family: Verdana,Arial,Helvetica,sans-serif;"><strong>Envoltura<br />
Espesor promedio (mm)<br />
Cantidad conductor</strong></span></td>
<td colspan="4" width="30%" bgcolor="#999999">
<span style="font-size: xx-small; color: #ffffff; font-family: Verdana,Arial,Helvetica,sans-serif;"><strong>Diámetro espesor<br />
aproximado (mm)<br />
Cantidad conductor</strong></span></td>
<td width="10%" bgcolor="#999999">
<span style="font-size: xx-small; color: #ffffff; font-family: Verdana,Arial,Helvetica,sans-serif;"><strong>Resistencia<br />
mínima aislación a 70º</strong></span></td>
<td width="10%" bgcolor="#999999">
<span style="font-size: xx-small; color: #ffffff; font-family: Verdana,Arial,Helvetica,sans-serif;"><strong>Tensión<br />
entre<br />
electrodos </strong></span></td>
</tr>
<tr>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">2</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">3</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">4</span></td>
<td width="7%" height="22">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">5</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">2</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">3</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">4</span></td>
<td width="9%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">5</span></td>
<td width="11%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">(MT.km)</span></td>
<td width="10%">
<p><span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">(Kv.CA)*</span>
</td>
</tr>
<tr>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.75</span></td>
<td width="9%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.6</span></td>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.8</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.8</span></td>
<td width="8%" height="22">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.8</span></td>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.9</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">7.6</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">8.0</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">8.6</span></td>
<td width="9%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">9.6</span></td>
<td width="11%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.011</span></td>
<td width="10%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">4</span></td>
</tr>
<tr>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.00</span></td>
<td width="9%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.6</span></td>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.8</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.8</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.8</span></td>
<td width="7%" height="22">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.9</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">8.0</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">8.4</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">9.4</span></td>
<td width="9%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">10.0</span></td>
<td width="11%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.010</span></td>
<td width="10%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">4</span></td>
</tr>
<tr>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.50</span></td>
<td width="9%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.7</span></td>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.8</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.9</span></td>
<td width="8%" height="22">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.0</span></td>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.1</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">9.0</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">9.8</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">11.0</span></td>
<td width="9%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">12.0</span></td>
<td width="11%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.010</span></td>
<td width="10%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">4</span></td>
</tr>
<tr>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">2.50</span></td>
<td width="9%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.8</span></td>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.0</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.1</span></td>
<td width="8%" height="22">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.1</span></td>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.2</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">11.0</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">12.0</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">13.0</span></td>
<td width="9%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">14.0</span></td>
<td width="11%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.0093</span></td>
<td width="10%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">6</span></td>
</tr>
<tr>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">4.00</span></td>
<td width="9%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.8</span></td>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.1</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.2</span></td>
<td width="8%" height="22">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.3</span></td>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.3</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">12.3</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">13.3</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">14.8</span></td>
<td width="9%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">16.2</span></td>
<td width="11%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.0076</span></td>
<td width="10%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">6</span></td>
</tr>
<tr>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">6.00</span></td>
<td width="9%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.8</span></td>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.3</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.4</span></td>
<td width="8%" height="22">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.4</span></td>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.5</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">16.0</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">17.2</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">18.9</span></td>
<td width="9%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">21.0</span></td>
<td width="11%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.0054</span></td>
<td width="10%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">6</span></td>
</tr>
<tr>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">10.00</span></td>
<td width="9%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.0</span></td>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.5</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.5</span></td>
<td width="8%" height="22">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.6</span></td>
<td width="7%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">1.6</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">19.9</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">21.2</span></td>
<td width="8%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">23.6</span></td>
<td width="9%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">25.9</span></td>
<td width="11%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">0.0053</span></td>
<td width="10%">
<span style="font-size: xx-small; font-family: Verdana,Arial,Helvetica,sans-serif;">6</span></td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.electricasas.com/electricidad/instalaciones-electricas-electricidad-2/materiales/conductores/conductores-iram-2342-2158-y-2179/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
	</channel>
</rss>
